Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

Product Details
Customization: Available
Function: Automatic Control
Certification: RoHS, ISO: 9001, CE
Still deciding? Get samples of US$ 290/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
>2000 square meters
  • Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
  • Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
  • Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
  • Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
  • Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • Product Parameters
  • Installation Instructions
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTH3 C57-103S2
Condition
New
Customized
Customized
Material
Plastic
Product Model
C57-A3
Order Number
Cth3 C57-103s2
Rated Input Voltage
24V DC
Programming Software
Codesys V3.5 (Sp18 Version)
Programming Language
Programming Language According to IEC61131-3: CFC/
User Program Space
32m
Power off Hold Space
64kb
Maximum Number of Racks
4
Ethercat Maximum Number of Extended Slav
up to 128 Ethercat Slave Modules , Each Ethercat S
Specification
34*115*101.6 (mm)
Trademark
COTRUST
Origin
China
HS Code
85371011
Production Capacity
50000pieces/Year

Product Description

Product Description

Order No.:CTH3 C57-103S2
Specification: 32MB program data space,64KB power-off hold data,55M expansion bus,24VDC power supply,10 channels digital input,6*500KHZ high-speed counter,1*RS485 port,1*EtherNET port,1*USB port,,1*CAN port,1 *EtherCAT port; Maximum number of racks :4 (including local racks) Support up to 128 EtherCAT slave stations and support CODESYS programming platform SP18 version.

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
 

Our Advantages
 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

 

 

Product Parameters
Product model C57-A3
Order number CTH3 C57-103S2
Physical characteristics
Size (WxHxD) 34×115×101.6 mm
Power loss 19.2W
Power supply characteristic
Rated input voltage 24V DC
Input voltage range 20.4V~28.8V DC
Input current   0.8A
Polarity reverse protection Yes
Bus power voltage  +5V DC
Bus power current 1.6A
LED indicator characteristics
24V Power indicator (green)  On: 24VDC power supply is normal; Off: No 24VDC power supply.
SF Indicator (red) On: The system is faulty. Off: no error. 
BF indicator (red) On: The bus is faulty. Off: no error. 
RUN indicator (green)  On: The system is running. OFF: The system stops.
STOP indicator (yellow) On: The system stops. Off: The system is running
Ethernet indicator Link 1 indicator(Green) On: Connect; Off: No connection
SPEED 1 indicator(Yellow)  On: 100Mbps; Off: 10Mbps
EtherCAT indicator LINK 2 indicator(Green)   On: Connected; Off: Not connected
SPEED 2 indicator(Yellow)  On: 100Mbps; Off: 10Mbps
IO indicator 10.0~11.1(Green)  ON: Signal input; Off: No signal input
Instruction performance
Bit instruction execution speed 15ns
Floating point instruction execution speed 45ns
Data storage specification  Zone I 32K,Zone Q 32K,Zone M 512K
Internal memory 
User program space 32M
Power off hold space 64KB
Integrated communication function
Bus interface Support
USB port 1
EtherNET port 1
RS485 port 1
EtherCAT port 1
CAN port 1
EtherCAT port
Communication interface    1*EtherCAT port
Baud rate  100Mbps adaptive
Protocol type  EtherCAT Interface protocol
Maximum cable length per section 100m
Maximum number of sites Each master supports a maximum of 128 EtherCAT slave stations
Support function Support distributed clock configuration, redundancy Settings
Support startup parameter configuration
Support PDO parameter configuration and mapping 
Support for bus cycle configuration, configure startup check vendor ID and product ID
Isolate Yes
RS485 communication port
Number of communication interfaces  1,PORT0
Communication protocol  Free port protocol (built-in MODbus-RTU protocol)
Free port baud rate Ranges from 1.2Kbps to 115.2Kbps
Maximum cable length per section Use isolation repeater: 1000m(115.2Kbps)
                                          1200m(38.4 kbps)
Isolation repeater not used: 50m
Maximum number of sites 32 stations per segment, 126 stations per network.
Isolate  Communication port isolation
CANopen port
Communication interface CANopen
Protocol type  32
Protocol type  CANopen DS301 standard protocol
Support function Support automatic start CANopen Manager 
Support Optional slave polling
Support starting the slave station
Support NMT 
Support synchronous production
Support synchronous consumption
Support heartbeat generation 
Support activation time creation
Transmission rate (kbit/s) 1000 800 500 250 125 50 20
Maximum length (m) 25 50 100 250 500 1000 2500
Isolate Communication port isolation
EtherNET communication port
Communication interface   1*EtherNET port
Baud rate  10/100Mbps adaptive
Protocol type  CODESYS custom protocol, based on UDP and TCP(Ethernet programming and CPU support
Maximum cable length per section 100m
Maximum number of connections for a site UDP supports a maximum of 16 connections
Isolate Communication port isolation
Programming Software 
Programming package CODESYS V3.5 (SP18 version)
Programming language   Programming language according to IEC61131-3: CFC/FBD/LD/IL/ST/SFC
Protection function
Power supply protection The power supply terminal provides reverse protection and surge absorption functions
Interface protection Lightning protection for communication ports
Local I/O scalability
Maximum number of racks 4
Maximum number of modules Host rack: 11 (power module, CPU, trunk module, 8 signal modules)
Slave rack: 10 (power module, trunk module, 8 signal modules)
Remote I/O expansion capability
CAN extended maximum number of master stations 1
CAN maximum number of slave stations Each master station connects to a maximum of 32 CAN slave stations. 
EtherCAT maximum number of extended slaves Up to 128 EtherCAT slave modules , each EtherCAT slave module has a maximum of 8 signal modules
Supports motion control function
Motion control function   Do not support SoftMotion and CNC
Real-time clock
Power off hold space The power failure holding time is about 112 hours (typical value), and the power failure holding time can reach at least 1 year after the external battery is connected
Precision  Monthly deviation <60 seconds
Digital input characteristics
Native integrated IO points 10
Input type   Drain type/source type
Rated voltage 24V DC
Input voltage range  20.4~28.8V DC
Surge voltage  35V DC for 0.5s
Logic 1 Signal (min) 15 VDC,2.5mA
Logical 0 signal (Max) 5 VDC,1mA
Connect 2-wire Proximity Switch Sensor (BERO) 1mA (maximum allowable leakage current)
Input filtering Configurable, supporting 0.2us, 0.4us, 0.8us, 1.6us, 3.2us, 6.4us, 12.8us, 0.2ms, 0.4ms,0.8ms, 1.6ms, 3.2ms, 6.4ms, 12.8ms, default is 6.4ms
Isolation (field vs. logic)  500V AC,1minute
Simultaneous connected input 10
Maximum cable length per section 500 m (standard input)
Shield 50m (high speed counter input)
Unshielded   300 m (standard input)
Pulse capture input 10
High count counter  Total 6
Single-phase 6×500KHz
Two-phase 4×250KHz
Installation Instructions

ower interface definition

 

 

4 detachable terminals (spacing 3.50mm)

 

Symbol 

 

 Signal definition

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust 

L+

 

24V power supply positive

M

 

24V power supply negative

 

 

24V power supply GND

--

--

 

 

USB interface definition

 

 

USB interface  

 

Bit number

 

Signal

 

Signal definition

 Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

1

V_BUS

 

+5V power supply

2

Data-

 

Data negative

3

Data+

 

Data positive

4

GND

 

GND

 

EtherNET/EtherCAT interface definition

 

Dual network-port interface

 

Bit number

 

Signal

 

Signal definition

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

1

TX+

 

Data sending end

2

TX-

Data sending negative end

3

RX+

Data receiving terminal

4

TERM

--

5

TERM

--

6

RX-

Data receiving negative end

7

TERM

--

8

TERM

--

 

Connector housing

PE

 

Casing grounding

 

 

RS485/CAN Communication interface definition

 

Single port interface

 

Bit number

 

Signal

 

Signal definition

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

1

CAN_H

 

Data sending positive end

2

CAN_L

 

Data sending negative end

3

--

--

4

A0

 

RS485 signal A

5

B0

 

RS485 signal B

6

--

--

7

CAN_GND

 

CAN/RS485 signal GND

8

--

--

 

Connector housing

PE

 

Casing grounding

 

 

System running DIP switch definition

 

System run switch

 

Symbol

 

 

Dip direction

 

Signal definition

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust 

RUN

UP

System operation

STOP

Down

System stop

 

Installation specification

1. Use DIN35 standard guide rail.

2. Installation size diagram:

 C57-A3 motion controller has mounting holes, which can be easily installed on the backplane. Figure 3-2 shows the installation dimensions.

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust
Company Profile

Cth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, CotrustCth3 C57-103s2, PLC, 32kb Program Data Space, 64kb Power-off Hold Data Space, 55m Expansion Bus, 10 Digital Inputs, 2 RS485 Ports, 1 Ethernet Port, Cotrust

FAQ

Q1.What's the payment term? 
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.

 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed