CTH200 series PLC is a kind of automatic controller product introduced by COTRUST, which aiming at the rapidly developing OEM market in China. Fuled by the abundant experience of COTRUST engineers and the quick response to marketing demand of industry 4.0, it owns traits from rich-model to Ethernet to excellent performance. CTH200 series PLC will not just offering OEM clients with cost-effective solution of micro automation, but speed the development process of industry 4.0 in China. CTH200 is a general terms for all CPU products(nine types in all), including CPU H224, CPU H226L, CPU H224X, CPU H226XL and CPU H228XL(the CPU H228XL is just relay-output while others support both relay and transistor ). Supporting for variety of modules, such as digital I/O modules, analog I/O modules, temperature sampling modules and so on gives you flexible choice in front of industrial automation problem. CTH200 PLC communicates with computer via Ethernet port or RS485 port, and programs on MagicWorks PLC (version V2.08 or above) or MicroWin(not suit for Ethernet port). CTH200 system can be made up by one single CPU as well as one CPU with up to 7 variousoptional expansion modules. |
Performance Parameters
Function Type |
Description |
|||
Dimension(W×H×D) |
H224/H224X:137×80×62mm |
H226L/H226XL:196.5×80×62mm |
||
Bit instruction processing speed |
0.22µs |
0.15µs |
||
Float instruction processing speed |
12µs |
8µs |
||
Program memory |
8+4KB |
H224X: 12+4KB H226XL: 24+48KB |
||
Data memory |
8KB |
H224X: 8+100KB H226XL:10+100KB |
||
Power failureprotection |
The max.8KB |
The max.10+100KB,200 hours |
||
Ways to powerfailure protection |
FlashROM |
Supercapacitor+Battery |
||
Digital I/O |
128DI/128DQ |
640DI/640DQ |
||
Analog I/O |
32AI/32AQ |
194AI/194AQ |
||
Bit storage area(M) |
256bit |
|||
Local memory(L) |
64byte |
|||
Sequential controlrelay(S) |
256byte |
|||
Pulse capture input |
14 |
14 |
||
High speed counter |
4*50KHz (HSC0~HSC3) Support 4 singal phase input,1 AB phase input(HSC0 supportAB phase) only support high speed count mode 0 and 9 |
6*50KHz (HSC0~HSC5) 4*30KHz (HSC3 and HSC5 both not support dual phase) |
||
High speed counter power input |
18~26V |
|||
High speed pulse output(Transistor output) |
motion control output:3*50KHz Q point output:Q0.0~Q0.2 |
motion control output:2*50KHz PTO/PWM:2*50KHz Q point output:Q0.0~Q0.1 |
||
Timer interruption |
2,1ms |
|||
Edge interruption |
4 rising edge/4 falling edge |
|||
Max extension module |
7 |
|||
BD extension board |
1 |
|||
System indicator lamp |
SF indicator lamp(red):ON=error,OFF=normal |
|||
RUN indicator lamp(green):ON=run,OFF=stop |
||||
STOP indicator lamp(orange):ON=stop,OFF=run |
||||
RMC indicator lamp(green):ON=allow,OFF=forbid |
||||
LINK/ACT indicator lamp(green):ON=link,flash=transfer,OFF=stop |
||||
Analog potentiometer |
-- |
2,8-bit resolution |
||
Real-time clock |
Build-in,precision ±120s/m. |
|||
Programming card |
support(download program to PLC can choice "coverage/no coverage" "program block/data block" ) |
|||
Battery card |
-- |
support |
||
Memory card |
-- |
support |
||
Timer |
Total amount:256 1ms:4 |
Total amount:512 1ms:4 10ms:272 100ms:236 |
||
Counter |
256(Power failure protection) |
H224/H226L |
H224X/H226XL |
|
RS485 communication |
||
Communication protocol |
H224/H224X:2 RS485 port,1 PPI,1 FPORT H226L/H226XL:2 RS485 port,1 PPI/FPORT |
|
PPI baud rate |
baud rate:9.6Kbps,19.2Kbps,187.5Kbps |
|
FPORT baud rate |
FPORT baud rate:1.2Kbps~115.2Kbps |
|
Maximum cable length |
Isolated repeater applied:When it is 1000 m, baud rate is 187.5Kbps; when it is 1200 m, 38.4Kbps. Isolated repeater unapplied:50m |
|
Maximum number of stations |
32 stations per segment,126 stations per network |
|
Maximum number ofmaster stations |
32 |
|
Interface |
2 RS485 port |
|
Isolated |
-- |
Digital Input Features |
|||
H224/H224X |
H226L/H226XL |
||
Number of integrated digital input |
14 |
24 |
|
Input type |
Sink/ Source |
||
Rated voltage |
24VDC |
||
Voltage input |
20.4~28.8VDC |
||
Surge voltage |
35VDC,last 0.5s |
||
Logical 1 Signal (minimum) |
15 VDC,2.5mA |
||
Logical 0 Signal (Maximum ) |
5 VDC,1mA |
||
Maximum permissible leakage current |
1mA |
||
Filtering input |
H224 and H226Lsupport 3.4ms,6.4ms;H224X andH226XL support0.2ms,0.4ms,0.8ms,1.6ms,3.2ms,6.4ms,12.8ms,default6.4ms |
||
Isolated(field side to logical circuit) Isolated groups |
500V AC,1 minute |
||
Simultaneous inputs |
14 |
24 |
|
Maximum cable length Shielded Unshielded |
500m(standard input),50m(high-speed counters input) 300m(standard input) |
Digital Output Features |
|||||||
Output type |
Transistor |
Relay |
|||||
H224/H226L |
H224X/H226XL |
H224/H226L |
H224X/H226XL |
||||
Type |
MOSFET,Source |
dry contact |
|||||
Rated voltage |
24VDC |
24VDC or 110V/220VAC |
|||||
Voltage input |
20.4~28.8VDC |
5~30VDC:5~250VAC |
|||||
Surge voltage(Maximum) |
8A,100ms |
5A,4s@10% duty ratio |
|||||
Rated current(maximum) |
0.5A |
2.0A |
|||||
Rated current(maximum) |
6A |
8A |
|||||
lighting load(maximum) |
5W |
DC 30W,AC 200W |
|||||
On-Resistance |
0.3Ω,max 0.6Ω |
0.2Ω |
|||||
Isolated(field side to logical circuit)
|
500VAC,1 minute |
1500VAC,1 minute |
|||||
Delayoutput |
off to run |
Transistor H224/H226L:max .15μs Relay H224/H226L:max .50μs TransistorH224X/H226XL:2μs(Q0.0, Q0.1),max .15μs Relay H224X/H226XL:max .10ms |
|||||
Run to off |
Transistor H224/H226L:max .130μs Relay H224/H226L:max .200μs TransistorH224X/H226XL:10μs(Q0.0, Q0.1),max .130μs Relay H224X/H226XL:max .10ms |
||||||
Service time |
-- |
10,000,000(non-loaded) |
|||||
Service time |
100,000(2A) |
||||||
Simultaneous output |
H224/H224X:10 H226L/H226XL:16 |
||||||
Parallel output |
no |
yes |
|||||
Maximum cable length |
Shielded |
500m |
|||||
Unshielded |
150m |
Connector |
PIN |
PORT0(RS485) |
FPORT0(RS485) |
|
1 |
Shell Grounded |
Shell Grounded |
2 |
logically |
logically |
|
3 |
RS485+signal B |
RS485+signal B |
|
4 |
Send the application RTS |
Send the application RTS |
|
5 |
logically |
logically |
|
6 |
+5V, series connection 100 Ω resistance |
+5V, series connection 100 Ω resistance |
|
7 |
+24V |
+24V |
|
8 |
RS485-signal A |
RS485-signal A |
|
9 |
NC |
NC |
|
shell |
Shell Grounded |
Shell Grounded |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.