Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CTH200 series PLC is a kind of automatic controller product introduced by COTRUST, which aiming at the rapidly developing OEM market in China. Fuled by the abundant experience of COTRUST engineers and the quick response to marketing demand of industry 4.0, it owns traits from rich-model to Ethernet to excellent performance. CTH200 series PLC will not just offering OEM clients with cost-effective solution of micro automation, but speed the development process of industry 4.0 in China. CTH200 is a general terms for all CPU products(nine types in all), including CPU H224, CPU H226L, CPU H224X, CPU H226XL and CPU H228XL(the CPU H228XL is just relay-output while others support both relay and transistor ). Supporting for variety of modules, such as digital I/O modules, analog I/O modules, temperature sampling modules and so on gives you flexible choice in front of industrial automation problem. CTH200 PLC communicates with computer via Ethernet port or RS485 port, and programs on MagicWorks PLC (version V2.08 or above) or MicroWin(not suit for Ethernet port). CTH200 system can be made up by one single CPU as well as one CPU with up to 7 variousoptional expansion modules. |
Performance Parameters
Physical Features CTH2 216-2AX35-0X40 |
|
Dimension(W×H×D) |
196.5×80×62mm |
Power dissipation |
11W |
Memory Features |
|
Program memory |
24KB+48KB |
Data memory |
10KB+100KB |
General Features |
|
Timers total 1ms 10ms 100ms |
512 4 272 236 |
Counters total |
256 |
Internal memory bits |
256 |
Stored permanently on power down |
Data permanent stored |
Sequential control relay (S) |
256 |
Time Interrupts |
2*1ms resolution |
Edge Interrupts |
4 rising edges and/ or 4 falling edges |
Analog adjustment |
Non |
Boolean execution speed |
≤0.15µs |
Float execution speed |
≤8µs |
Clock |
embedded ,precision ±120s/m |
BD expansion board interface number |
1,Support CAN expansion board, analog expansion board |
System indicator |
5,STOP,RUN,SF,RMC,LINK/ACT |
RUN/STOP dial code |
Yes,2 |
Battery card interface |
Support,power supply below 2V,alarm bit SM195.0 |
Programming card and Memory card |
Support |
Rated input voltage |
24VDC |
Power supply Native and extended bus+5V +24V |
660mA 200mA |
Integrated Communication Function |
|
Communication Interface |
2 communication ports ,PORT0:PPI/Free port,RS485;FPORT0:PPI/Free port,RS485 After plugging in the RS485 expansion board and restarting, PORT0 (RS485, PPI communication port) PORT1 (RS485, PPI/ free communication port), FPORT0 (free port) |
PPI baud rates(baud) |
9.6k,19.2k and 187.5k |
Freeport baud rates(baud) |
1.2k ~ 115.2k |
Maximum cable length Isolated repeater applied Isolated repeater unapplied |
When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k. 50m |
Maximum number of stations |
32 stations per segment,126 stations per network |
Maximum number of masters |
32 |
Point-to-point (PPI master station mode) |
Yes(NETR/NETW), maximum 8 connections, and each connection has a maximum communication of 200 bytes |
MPI communication |
(1PG/1OP) 8 in total, 2 reserved |
Ethernet Function |
|
Communication port |
1 Ethernet port |
Communication standard |
IEEE802.3 standard |
Communication speed |
10Mbps and 100Mbps self-adaption |
Adaptive cross connection |
Non support |
Interface to industrial Ethernet(10/100Mbps) |
RJ45 port |
Protocol type |
UDP/TCP protocol Support PDP_PPI, MODBUS_TCP, Socket, S7 protocols, support PLC Ethernet communication, support MiCo Ethernet programming. |
Collocation method |
Support the upper computer through the Ethernet port search PLC, support the mouth download system configuration. |
Application interface |
Support MiCo service, UDP_PPI, Modbus_TCP, S7 protocol, Socket programming.Support Ethernet port online firmware upgrade function. |
Maximum number of connections |
8 UDP_PPI, no master or slave 8 Modbus_TCP, no master or slave 4 Socket connections, 2 UDP, 2 TCP 8 S7 protocol, no master and slave, COTRUST PLC only as slave station |
User data number |
Up to 200 bytes for UDP_PPI transmission. Up to 240 bytes are used for ModBus_TCP transmission. A maximum of 512 bytes is used for Socket transmission Up to 200 bytes for S7 transmission |
Port |
local:1~65535 remote server:8888 |
Boot time or restart time after reset |
3 seconds |
Indicator lamp |
Green RMC indicator: on: remote control in effect, off: remote control out Green Ethernet indicator: on: connection, flicker: transmission; out: not connected |
Maximum cable length |
100m |
Isolation |
Communication port isolation |
Integrated Communication Function (CANopen) - use for CAN communication board model CTH2-CAN-01S2-EB |
|||||||||||||
Communication Interface |
1(8 Pin) |
||||||||||||
Communication speed (kbps) |
1000 |
800 |
500 |
250 |
150 |
50 |
20 |
||||||
Maximum cable length(m) |
25 |
50 |
100 |
250 |
500 |
1000 |
2500 |
||||||
Maximum station address quantity |
127 |
||||||||||||
Station address range |
1-127 |
||||||||||||
Maximum number of master stations connect to slave stations |
32 |
||||||||||||
Collocation method |
CAN configuration blocks and EDS files |
||||||||||||
Maximum digital access |
Nomal IO |
CANopen IO |
|||||||||||
Byte |
Memory starting address |
Byte |
Memory starting address |
||||||||||
Input |
16 |
IB0 |
Input |
64 |
IB16 |
||||||||
Output |
16 |
QB0 |
Output |
64 |
QB16 |
||||||||
Maximum analog access |
Nomal IO |
CANopen IO |
|||||||||||
Channel |
Memory starting address |
channel |
Memory starting address |
||||||||||
Input |
32 |
AIW0 |
Input |
162 |
AIW64 |
||||||||
Output |
32 |
AQW0 |
Output |
162 |
AQW64 |
||||||||
Integrated Communication Function (CANopen) - use for CAN communication board model CTH2-CAN-01S2-EB |
|||||||||||||
Protocol |
CanFree |
||||||||||||
Use method |
Supported by internal library instructions |
I/O Features |
|
Number of integrated digital inputs |
24 |
Input type |
Sink/Source |
Number of integrated digital outputs |
16 |
Output type |
Solid-MOSFET |
Digital I/O mapping domain |
640DI/640DQ |
Analog I/O mapping domain |
194AI/194AQ |
Maximum number of expandable I/O module |
7 |
Maximum digital I/O configuration |
IO:256(128DI/128DO) |
Maximum analog I/O configuration |
64(32AI/32AQ) |
Pulse catch inputs |
24 |
High-speed counters Total Uniphase counters Bi-phase counters |
6 6×50KHz 4×30KHz |
Digital Input Features |
|
Number of integrated digital input |
24 |
Input type |
Sink/ Source |
Rated voltage |
24V DC |
Maximum continuous permissible voltage |
30V DC |
Surge voltage |
35V DC,continuously 0.5s |
Logical 1 Signal (minimum) Logical 0 Signal (Maximum) |
15 VDC,2.5mA 5 VDC,1mA |
Isolation(field side to logical circuit) |
500V AC,1min |
Simultaneous input |
24 |
Maximum cable length Shielded Unshielded |
500 M(standard input) 50 M(high-speed counters input) 300 M(standard input) |
Digital Output Features |
|
Number of integrated digital output |
16 |
Output type |
Solid-MOSFET,source |
Rated voltage |
24VDC |
Output voltage range |
20.4~28.8VDC |
Logical 1 Signal (minimum) |
20VDC,max current |
Logical 0 Signal (Maximum) |
0.1V DC,10KΩ load |
Rated current per point |
0.5A |
Rated current for each common point |
4A |
Leakage current (maximum) |
10uA |
Surge current(Maximum) |
8A,100ms |
Lamp load (maximum) |
5W |
On resistance (contact) |
Typical 0.3Ω,max 0.6Ω |
Isolation(field side to logical circuit) |
500VAC,1mins |
Delay |
Off to on:2us(Q0.0, Q0.1),---15us on to off:10us(Q0.0, Q0.1),---130u |
High speed pulse output Maximum frequency |
Motion control library instruction: 2 channel 100KHz Pulse (Q0.0,Q0.1),Dir (Q0.2,Q0.3) PTO/PWM: 2 channel 20KHz (Q0.0,Q0.1) |
Simultaneous input |
All output point |
Parallel output |
Only when the outputs are in the same group |
Maximum cable length Shielded Unshielded |
500m 150m |
* Support new V2 programming card
* Ultracapacitors power-off protection time 10 hours and extended batteries for 200 days
* Alarm function for insufficient battery power of the battery card: when it is lower than 2V, the alarm bit SM195.0
Wiring diagram
RS485 communication port definition
Connector |
PIN |
PORT0(RS485) |
FPORT0(RS485) |
|
1 |
Shell Grounded |
Shell Grounded |
2 |
logically |
logically |
|
3 |
RS485+signal B |
RS485+signal B |
|
4 |
Send the application RTS |
Send the application RTS |
|
5 |
logically |
logically |
|
6 |
+5V, series connection 100 Ω resistance |
+5V, series connection 100 Ω resistance |
|
7 |
+24V |
+24V |
|
8 |
RS485-signal A |
RS485-signal A |
|
9 |
NC |
NC |
|
shell |
Shell Grounded |
Shell Grounded |
RS485 expansion board communication interface
Module interface and connector |
PIN |
FPORT0(RS485) |
Note:when terminal resistors are needed, |
1 |
RS485+signal B |
2 |
RS485-signalA |
|
3 |
Terminal resistance |
|
4 |
Shell Grounded |
|
5 |
RS485 signal GND |
|
6 |
NC |
|
7 |
NC |
|
8 |
NC |
|
9 |
NC |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.