• Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC
  • Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC
  • Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC

Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC

Task: Program
Structure: Combination
Signal: Continuous
Function: Automatic Control
Certification: RoHS, ISO: 9001, CE
Condition: New
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTS7-277-0PN32
Customized
Customized
Communication Protocol
Profinet
Number of Expansion Modules
8
Communication Rate
100Mbps
Topological Structure
Star Shaped, Tree Shaped, Linear, and Circular Str
Transport Package
CTN
Specification
71*80*62mm
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

1,Profinet bus communication rate 100Mbps,the maximum communication distance up to 100m between two slave module(100BASE-TX).

2,The topological structure support star,tree,linear,ring structure.

3,Each slave module allow to extend 8 I/O module(digital module,analog module,temperature module,PID module.but CAN module,motion control module,weighting  module are not include).

4,Support Siemens Profinet master station,Siemens S7-300,Siemens S7-1200,Siemens S7-1500.Support  Modbus RTU,PPI,Mitsubishi,Omron,Delta protocol.

5,Programming software TIA Portal V13 and above version.
 

Product Description
Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC

Order No.: CTS7277-0PN32
Specification: TrustPLC CTSC-200 EM277PN PROFINET slave modules, 100Mbps, 8 expansion modules, do not support EM253, weighing modules and communication modules



Technical

Physical Features

Dimension(W×H×D)

71×80×62 mm

Power Consumption

Rated voltage input

24V DC

Voltage range

20.4V~28.8V DC

Current input

0.8A

Bus power voltage

+5V DC

Bus power current

1.1A

Isolation

The external power supply is isolated from the system power supply

Power protection

provides reverse connection protection and surge absorption

LED Indicator

24V Indicator(Green)

ON = 24VDC power

OFF = 24VDC no power

SF Indicator(red)

ON = extend I/O Bus failure or PROFINET module failure

OFF = no fault

BF Indicator(red)

ON = PROFINET Bus communication failure (no connection to switch, no network detected)

Blinking=Hardware configuration is inconsistent

OFF = no fault

MT Indicator(yellow)

(maintenance indicator )

ON = Loss of synchronization

OFF =  no fault

P1R/P2Rport Indicator(green)

ON = There is a connection to the switch /PN master station

OFF = There is no a connection to the switch /PN master station

P1R/P2RportIndicator(yellow)

ON = received data

OFF = no received data

 

Expansion I/O

Maximum support module

8(digital module,analog module,temperature module and PID module,other moudle is not included)

Protocol

CTSC-200 PLC 4MHZ Bus protocol

Maximum  IO each station

Analog IO up to 64AI/32AQ

Digital IO up to 256DI/256DQ

Topological structure

support star,tree,linear,ring structure.

PROFINET port

Communication port

1*dual RJ45 port

Data transmission rate

Ethernet speed rate 10Mbps

PROFINET speed rate100Mbps

Support Ethernet

ping,arp,(SNMP)/MIB-2,LLDP

Send

250us~4ms

The third partPROFINET master station

Support

Maximum distance

100m(100BASE-TX)

Topological structure

support star,tree,linear,ring structure.

Isolation

Communication port isolation

Hardware configuration function

File type

PROFINET GDS file XML format

The third partPN master station

Add CTS7 277-0PN32 then support 8pcs expansion model

digital module,analog module,temperature moduleand PID module,other moudle is not included

Environmental condition
Temperature -40ºC ~+70ºC
Humidity 10%~95% no condensation
Electromagnetic compatibility
Electrostatic discharge
IEC61000-4-2
Contact discharge: ±4KV
Air discharge: ±8KV
Electrical fast transient pulse train
IEC61000-4-4
Power line: 2KV, 5KHz
Signal line: 2KV, 5KHz (I/O coupling clamp )
        1KV, 5KHz (communications coupling clamp )
Surge IEC61000-4-5 Power line: 2KV(asymmetry), 1KV(symmetry)
Radiofrequency electromagnetic radiation
IEC61000-4-3
80MHz~1GHz, 10V/m, 80%AM (1KHz )
Radiofrequency field inductively conducts interference
IEC61000-4-6
0.15MHz~80MHz, 10V/m, 80%AM (1KHz )
DC power input port short - term interruption and voltage variation
IEC61000-4-29
Interruption time: 10ms
Run in high temperature IEC60068-2
Run in low temperature IEC60068-2
65ºC, stay time: 24h, temperature change rate≤1ºC/min, recovery time≥1h
-20ºC, stay time: 24h, temperature change rate≤1ºC/min, recovery time≥1h
Start in high temperature IEC60068-2
Start in low temperature IEC60068-2
65ºC, 2h, not boot 3 times after temperature stable
-20ºC, 2h not boot 3 times after temperature stable
Cycle operation both high and low temperature
IEC60068-2
-10ºC~60ºC stay time:3h temperature change rate 1ºC/min, 5 loop, recovery time 1h
Store in high temperature IEC60068-2
Store in low temperature IEC60068-2
75ºC, stay time: 72h temperature change rate≤1ºC/min, recovery time≥1h
-40ºC, stay time: 72h temperature change rate≤1ºC/min, recovery time≥1h
Hot and cold shock IEC60068-2 -40ºC~75ºC, stay time: 3h, temperature change time: 2min, 3 loops
Stable high humidity IEC60068-2 Store temperature: 40ºC, stay time: 48h, 
store humidity: 93%
Alternate damp and hot
IEC60068-2
25ºC~55ºC, humidity: 95%, single loop: 24h, 2 loops
Sine shake(bare) IEC60068-2 5~150Hz, 0.05G2/Hz
150Hz~500Hz, -3dB/oct, 1h/axis, X, Y, Z 3 axes in all
Mechanical shake(bare)  IEC60068-2 15G, 11ms pulse, 3 times/direction
Fall 1m, 10 times, package
 
Company Profile
Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC
Cotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLCCotrust Profinet Slave Module Em277pn32 Compatible Siemens PLC
FAQ

Q1.What's the payment term? 
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now