Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CTSC-200 series is a new generation of high-performance PLC with high cost-effective,excellent performance,multi-protocol communication ports and a abundant instruction,which can apply to various of industries and adapt to the complex control requirements of small and medium control system.
Powerful communication capability
Ethernet communication mode:10/100Mbps Ethernet support MODBUS_TCP and UDP_PP protocol.Multiple host networking communication in the LAN, to programming, debugging and remote monitoring in the WAN.
PPI communication mode:CTSC-200 series CPU integrated 1-2 PPI port which hardware interface is the RS485 or RS232,provide communication rate 9.6Kbps,19.2Kbps,187.5Kbps,PPI is token-ring network structure,can form PPI network without relay,to complete data exchange through NETR and NETW,each exchange package can be up to 200bytes,each CPU can connect eight modules,that is each CPU can connect to 8 PC or other CPU.
If the I/O of some system is relatively too large that one CPU can not meet requirement,can achieve by several CPU,multi-CPU structure can achieve distributed control thant with high sstem reliability.The data exchange is extremely fast and convenient because of the powerful communication capability among different CPUs.
MPI communication mode:CTSC-200 series CPU can connect to the MPI network,communication rate 19.2Kbps,187.5Kbps which only work as slave station in the MPI network.The different slave stations can not communication each other while the master stations can read the data of slave station.
Profibus-Dp or Ethernet communication mode:CPU can be connected to the Profibus field by by DP slave stations,as salve station of certain master station,it can exchange data fast and real-time also can run independently which with high reliability.
CPU can be connected with industrial Ethernet by Ethernet module which is suitable for building control or other applications with several stations.
CANopen communication mode:To form network through CAN communication,each CAN master station can connect 32 CAN slave stations or devices,baud rate up to 1MBit/s within 25m,baud rate up to 20MBit/s within 2500m.
Freeport communication mode:CPUs provide 1-2 freeport,embedded several free communication protocol library such as Modbus,USS etc.
CPU 226L,CPU226H with two freeport can communicate simultaneously so as to meet the requirements of such occasions like high-speed communication ,synchronous control,many peripherals.
Specification |
EM231, 2AI×RTD |
EM231, 4AI×RTD |
Physical Features |
||
Dimensions(W×H×D) |
71.2×80×62mm |
71.2×80×62mm |
Power Loss(dissipation) |
1.7W |
1.7W |
Power Consumption | ||
From +5V(from I/O bus) |
87mA |
|
From L+ | 60 mA | |
L+ voltage range,class 2 or DC sensor supply | 20.4~28.8V DC | |
LED indicator | 24 VDC Power Supply Good: ON = no fault,OFF = no power ; SF: ON=module fault, Blink=input signal error, OFF=normal; |
|
Analog Input Features | ||
Input type | Module ground reference RTD | |
Input range |
RTD type(select one per module): |
|
Number of analog input points | 2 points | 4 points |
Isolation | ||
Field to Logic Field to 24V DC |
500V AC 500V AC 500V AC |
|
Common mode input range |
120V AC | |
Common mode rejection |
>120dB@120V AC |
|
Input resolution | ||
Temperature Resistance |
0.1ºC/0.1ºF 15 bits plus sign |
|
Measuring principle |
Sigma-Delta | |
Module update time for all channel | 425ms | 825ms |
Wire length to sensor, maximum | 100 m | |
Wire loop resistance | 20Ω, 2.7KΩ for Cu maximum | |
Suppression of interference | 85dB@ 50Hz/60Hz/400Hz | |
Data word format | Resistance: -27648 to +27648 | |
Maximum sensor dissipation | 1mW | |
Input impedance | ≥10MΩ | |
Maximum input voltage | 30 VDC (sensor), 5 VDC (source) | |
Input filter attenuation | -3dB@ 3.6kHz | |
Basic error | 0.1% FS(Voltage) | |
Repeatability | 0.05% FS | |
24V DC supply voltage range | 20.4 to 28.8 VDC |
You can wire the RTD sensors directly to the EM231 RTD modules, or you can use extension wires. Please use shielded wires to acquire best noise immunity. If you use shielded wires, connect the shield to the ground on pin 1 to 4 of the signal connector. This ground is the same ground as is present on the power connector pin 3 to 7. If you do not use an RTD input channel, you should wire a resistor to the unused channel inputs in order to prevent errors from floating inputs from blocking error indications from valid channels.
Connect user power to the power connector pin 1 and 2. You must connect pin 3 to a nearby chassis ground (Figure 2).
You can wire the RTD module to the sensor in three ways (shown in Figure 3). The most accurate mode is 4 wire (see Figure 3). The least accurate mode is 2 wire, which is only recommended if errors due to wiring can be ignored in your application.
Figure 1 Connector Terminal Identification for RTD Modules
The EM231 RTD modules provide a convenient interface to connect CTS7-200 PLC to several different RTDs. It also allows the CTS7-200 PLC to measure three different resistance ranges. You must use DIP switches to select RTD type, wiring configuration, temperature scale, and burnout direction. Both RTDs connect to a module must be of the same type.
The configuration DIP switches are located on the right bottom of the module, as shown in Figure 4. For the DIP switch settings to take effect, you need to power cycle the PLC or the 24V power supply.
Select RTD type by setting DIP switch 1 to switch 8 to correspond to the RTD as shown in Table 1 and Table 2.
Table 1 Selecting the RTD Type
RTD type |
SW1 |
SW2 |
SW3 |
SW4 |
SW5 |
100 Pt 0.003850(Default) | 0 | 0 | 0 | 0 | 0 |
200Ω Pt 0.003850 | 0 | 0 | 0 | 0 | 1 |
500Ω Pt 0.003850 | 0 | 0 | 0 | 1 | 0 |
1000Ω Pt 0.003850 | 0 | 0 | 0 | 1 | 1 |
100Ω Pt 0.003920 | 0 | 0 | 1 | 0 | 0 |
200Ω Pt 0.003920 | 0 | 0 | 1 | 0 | 1 |
500Ω Pt 0.003920 | 0 | 0 | 1 | 1 | 0 |
1000Ω Pt 0.003920 | 0 | 0 | 1 | 1 | 1 |
100Ω Pt 0.00385055 | 0 | 1 | 0 | 0 | 0 |
200Ω Pt 0.00385055 | 0 | 1 | 0 | 0 | 1 |
500Ω Pt 0.00385055 | 0 | 1 | 0 | 1 | 0 |
1000Ω Pt 0.00385055 | 0 | 1 | 0 | 1 | 1 |
100Ω Pt 0.003916 | 0 | 1 | 1 | 0 | 0 |
200Ω Pt 0.003916 | 0 | 1 | 1 | 0 | 1 |
500Ω Pt 0.003916 | 0 | 1 | 1 | 1 | 0 |
1000Ω Pt 0.003916 | 0 | 1 | 1 | 1 | 1 |
100Ω Pt 0.00302 | 1 | 0 | 0 | 0 | 0 |
200Ω Pt 0.003902 | 1 | 0 | 0 | 0 | 1 |
500Ω Pt 0.003902 | 1 | 0 | 0 | 1 | 0 |
1000Ω Pt 0.003902 | 1 | 0 | 0 | 1 | 1 |
Reserved | 1 | 0 | 1 | 0 | 0 |
100Ω Ni 0.00672 | 1 | 0 | 1 | 0 | 1 |
120Ω Ni 0.00672 | 1 | 0 | 1 | 1 | 0 |
1000Ω Ni 0.00672 | 1 | 0 | 1 | 1 | 1 |
100Ω Ni 0.006178 | 1 | 1 | 0 | 0 | 0 |
120Ω Ni 0.006178 | 1 | 1 | 0 | 0 | 1 |
1000Ω Ni 0.006178 | 1 | 1 | 0 | 1 | 0 |
10000Ω Pt 0.003850 | 1 | 1 | 0 | 1 | 1 |
10Ω Cu 0.004270 | 1 | 1 | 1 | 0 | 0 |
150Ω FS Resistance | 1 | 1 | 1 | 0 | 1 |
300Ω FS Resistance | 1 | 1 | 1 | 1 | 0 |
600Ω FS Resistance | 1 | 1 | 1 | 1 | 1 |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.