Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

Product Details
Customization: Available
Task: Program
Structure: Combination
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
>2000 square meters
  • Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
  • Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
  • Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
  • Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
Find Similar Products
  • Overview
  • Product Description
  • Our Advantages
  • Product Parameters
  • Installation Instructions
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTH3 H36-002S2
Signal
Continuous
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Material
Plastic
Weight
0.5kg
Product Model
H36-02
Programming Software
Magicworks PLC
Program Space
256kb+2*64kb
Data Space
1m
Power off Hold Space
32kb
Max Number of Racks
4
Ethercat Slave Stations
up to 64
Transport Package
CTN
Specification
34*115*101.6 (mm)
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description


 

Product Description
CPU H36-02 (CTH3 H36-002S2)
256KB+2*64KB program storage,
1MB data storage,
32KB data power-off storage,
24VDC power supply,
2xRS485 port (PPl/ free port),
1xEthernet port,
1xUSB port,
1xCAN port,
1xEtherNET/EtherCAT port,


Support single-axis motion control functions (such aspositioning,speed and backtracking, etc.)
Support linear/circular interpolation
Support continuous interpolation and spiral interpolation
Support electronic CAM and electronic gear, probe function
Support up to 64EtherCAT slave stations
Maximum number of racks is 4
Support Trace function
Support C language programming
Support Profinet intelligent slave function
Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
Our Advantages

Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

Product Parameters

 

 

Physical features

Dimension(W×H×D)

34×115×101.6 mm

Power dissipation

19.5W

Power supply features

Rated input voltage

24V DC

Input voltage range

20.4~28.8V DC

Input current

0.8A

Reverse polarity protection

Yes

Bus power supply voltage

+5V DC

Bus supply current

1.6A

LED indicator characteristics

24V power indicator (green)

On: 24VDC power supply is normal, off: no 24VDC power supply

 

SF indicator (red)

On: system failure, off: no error

BF indicator (red)

On: bus failure, off: no error

FRCE indicator (yellow)

On: items are forced, Off: no items are forced.< note > can also be controlled via the scrapers command.

 

RMC indicator (green)

On: CPU has successfully communicated with the remote server (dial switch 3 is ON and Ethernet port parameters have been configured correctly)

Off: CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch)

Run indicator (green)

On:system runs, off: the system stops

STOP indicator(orange)

On: system stops; Off: system runs

Ethernet indicator

Green

Flicker: connected, out: unconnected

Yellow

On:100Mbps,Off:10Mbps

Expand I/O capabilities

Maximum number of racks of 1CPU

4

Maximum number of modules supported per rack

Support up to 8 modules except  power, CPU, relay module

Function category

Feature

Describe

Communication function

Bus interface

Provides an extension module interface

USB port

Provide a USB main device interface

Standard Ethernet interface

1 Ethernet interface is provided

® supports Ethernet programming;

® supports UDP_PPI protocol: network read and write operation between CPUs (instruction mode UDPNETW/UDPNETR or instruction wizard mode);

® supports Modbus_TCP protocol;

RS485 port

H35-00:2*RS485 port

H36-00/H36-01:1*RS485 port

EtherCAT port

H35-00:None

H36-00/H36-01:1*EtherCAT port

 

CANopen port

H35-00/H36-00:None

H36-01:1*CANopen port

 

Storage capabilities

 

Program memory

H35-00:192KB;H36-00/H36-01:256KB

Data storage

H35-00:512KB;H36-00/H36-01:1MB

Power down to maintain data

H35-00:16KB;H36-00/H36-01:32KB

Expand I/O capabilities

Expand function

Maximum expansion of 32 I/O modules (4 racks, 8 modules per rack)

Isolation function

Power supply isolation

Isolation between external power and system power

Communication isolation

EtherNET,EtherCAT,RS485,CANopen isolation

Protection function

Power protection

Power supply end provides reverse connection protection function and surge absorption function

Interface protection

Communication port lightning protection

Programming function

Programming function

MagicWorks PLC provides LAD ladder diagram, instruction list STL two programming languages, programming software support Chinese/English.

Run switch

RUN/STOP

Reset IP configuration by flipping the switch five times within 3 seconds

(RUN from run-> STOP, RUN from stop-bbb>

 

PORT0:RS485 port

Number of communication ports and protocols

RS485 port(switchable PPI and free port protocol)

Communication baud rate

PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps

Free port :1.2Kbps~115.2Kbps,built-in Modbus master/slave function

Maximum cable length per segment

Use isolation repeater: 1000m (187.5kbps)

                1200m(38.4Kbps)

No isolation repeater: 50M

Maximum number of stations

Each segment with 32 stations and each network with 126 stations

Point to point (PPI main station mode)

Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time

MPI connection

A MPI slave station can connect up to 8 MPI masters

Isolation

Communication port isolation

RJ45 port

Communication protocol

H35-00

H36-00/H36-01

H36-01

PPI/MPI, free port (Modbus RTU)

EtherCAT

CANopen

Communication baud rate

PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps

100Mbps

20Kbps~1Mbps

Free port:1.2Kbps~115.2Kbps

   

Maximum cable length per segment

Use isolation repeater: 1000m (187.5kbps)

 1200m(38.4Kbps)

No isolation repeater: 50M

100m connection

Maximum 2500 m (20Kbps)

Minimum 25m (1Mbps)

Refer to CANopen communication port

 

 

Maximum number of stations

Each segment with 32 stations and each network with 126 stations

No limit

Each master station support a maximum of 32 slaves

Point to point (PPI main station mode)

Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time

--

--

MPI connection

A MPI slave station can connect up to 8 MPI masters

--

--

Isolation

Communication port isolation

EtherNET port

Communication port

1*EtherNET port

Baud rate

10/100Mbps adaptive

Protocol types

Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU

Maximum length of each cable

100m directly connected

Maximum number of connections per site

UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP

Quantity of user data

Up to 200 bytes for UDP_PPI transfer,

Up to 240 bytes for ModBus_TCP transmission,

A maximum of 512 bytes are used for Socket transmission

 

DHCP function

Support

Remote monitoring/programming

Support

Isolation

Communication port isolation

CANopen port

Communication port

--

1*CAN port

Maximum number of slave stations

1 master station can be connected maximum of 32 slave stations

Protocol types

CANopen DS301standard protocol

Support functions

Supports automatic starting of CANopen Manager

Supports optional slave polling

Support to start slave stations

Support NMT

Support synchronous production

Support synchronous consumption

Support heartbeat generation

Support activation time creation

Transmission rate(kbit/s)

1000

800

500

250

125

50

20

Maximum length(m)

25

50

100

250

500

1000

2500

Isolation

Communication port isolation

 

Installation Instructions

 

Power interface definition

4pin terminals spaced at 3.81mm apart

Symbol

Signal definition

 Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

L+

+24V power

M

+24V power ground

 

Ground

--

--

 

USB interface definition

USB port

No.

Signal

Signal definition

Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

1

V_BUS

+5V power

2

Data-

Data-

3

Data+

Data+

4

GND

Ground

 

EtherNET interface definition

RJ45 port

No.

Signal

Signal definition

 Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

1

TX+

Positive end of data transmission

2

TX-

Negative end of data transmission

3

RX+

Positive end of data transmission

4

TERM

--

5

TERM

--

6

RX-

Negative end of data transmission

7

TERM

--

8

TERM

--

Shell

PE

Shell ground

Green indicator

As an indication of EtherNET connection status

Yellow indicator

As an indication of EtherNET connection status

 

CAN interface definition

RJ45 port

No.

Signal

Signal definition

Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

1

CAN_H

Positive end of data transmission

2

CAN_L

Negative end of data transmission

3

--

--

4

--

--

5

--

--

6

--

--

7

CAN_GND

CAN Gound

8

--

--

Shell

PE

Shell ground
Green indicator

As an indication of CAN connection status

Yellow indicator

As an indication of CAN connection status

 

RS485 interface definition

Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart

6pin terminals 

Signal

Signal definition

 Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

A0

PORT0 RS485 signal A

B0

PORT0 RS485 signal B

SG

PORT0 RS485 signal ground

A0

PORT0 RS485 signal A

B0

PORT0 RS485 signal B

SG

PORT0 RS485 signal ground

 

Dial switch definition

Dial switch

Symbol

Dial direction

Signal definition

Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

RUN

Up

System operation

STOP

Down

System halt

 

Swivel 5 times in 3 seconds

Reset the IP configuration (once from run-> STOP and once from stop-> RUN)

DIP dial

No.

Symbol

Signal definition

Note

 Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

1

Term-PORT0

Terminal resistance switch 1(PORT0)

ON:with terminal resistance

OFF:without terminal resistance

2

Term-PORT1 (H35-00)

Terminal resistance switch 2(PORT1)

ON:with terminal resistance

OFF:without terminal resistance

NC (H36-00/H36-01)

--

--

3

RMC-SW

Remote control switch

ON:Remote control allow OFF:Remote control forbid

 

Certifications
Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust
Company Profile

Cth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, CotrustCth3 H36-002s2, PLC, 256kb+2*64kb Program Space, 1MB Data Space, 32kb Power-off Hold Data Space, 24VDC Power Supply, 2 RS485 Communication Ports, Cotrust

FAQ

Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.

 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now