Physical features |
||||
Dimension(W×H×D) |
34×115×101.6 mm |
|||
Power dissipation |
19.5W |
|||
Power supply features |
||||
Rated input voltage |
24V DC |
|||
Input voltage range |
20.4~28.8V DC |
|||
Input current |
0.8A |
|||
Reverse polarity protection |
Yes | |||
Bus power supply voltage |
+5V DC |
|||
Bus supply current |
1.6A |
|||
LED indicator characteristics |
||||
24V power indicator (green) |
On: 24VDC power supply is normal, off: no 24VDC power supply
|
|||
SF indicator (red) |
On: system failure, off: no error |
|||
BF indicator (red) |
On: bus failure, off: no error |
|||
FRCE indicator (yellow) |
On: items are forced, Off: no items are forced.< note > can also be controlled via the scrapers command.
|
|||
RMC indicator (green) |
On: CPU has successfully communicated with the remote server (dial switch 3 is ON and Ethernet port parameters have been configured correctly) Off: CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch) |
|||
Run indicator (green) |
On:system runs, off: the system stops |
|||
STOP indicator(orange) |
On: system stops; Off: system runs |
|||
Ethernet indicator |
Green |
Flicker: connected, out: unconnected |
||
Yellow |
On:100Mbps,Off:10Mbps |
|||
Expand I/O capabilities |
||||
Maximum number of racks of 1CPU |
4 |
|||
Maximum number of modules supported per rack |
Support up to 8 modules except power, CPU, relay module |
|||
Function category |
Feature |
Describe |
||
Communication function |
Bus interface |
Provides an extension module interface |
||
USB port |
Provide a USB main device interface |
|||
Standard Ethernet interface |
1 Ethernet interface is provided ® supports Ethernet programming; ® supports UDP_PPI protocol: network read and write operation between CPUs (instruction mode UDPNETW/UDPNETR or instruction wizard mode); ® supports Modbus_TCP protocol; |
|||
RS485 port |
H35-00:2*RS485 port H36-00/H36-01:1*RS485 port |
|||
EtherCAT port |
H35-00:None H36-00/H36-01:1*EtherCAT port
|
|||
CANopen port |
H35-00/H36-00:None H36-01:1*CANopen port |
|||
Storage capabilities
|
Program memory |
H35-00:192KB;H36-00/H36-01:256KB |
||
Data storage |
H35-00:512KB;H36-00/H36-01:1MB |
|||
Power down to maintain data |
H35-00:16KB;H36-00/H36-01:32KB |
|||
Expand I/O capabilities |
Expand function |
Maximum expansion of 32 I/O modules (4 racks, 8 modules per rack) |
||
Isolation function |
Power supply isolation |
Isolation between external power and system power |
||
Communication isolation |
EtherNET,EtherCAT,RS485,CANopen isolation |
|||
Protection function |
Power protection |
Power supply end provides reverse connection protection function and surge absorption function |
||
Interface protection |
Communication port lightning protection |
|||
Programming function |
Programming function |
MagicWorks PLC provides LAD ladder diagram, instruction list STL two programming languages, programming software support Chinese/English. |
||
Run switch |
RUN/STOP |
Reset IP configuration by flipping the switch five times within 3 seconds (RUN from run-> STOP, RUN from stop-bbb> |
PORT0:RS485 port |
|||
Number of communication ports and protocols |
RS485 port(switchable PPI and free port protocol) |
||
Communication baud rate |
PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps |
||
Free port :1.2Kbps~115.2Kbps,built-in Modbus master/slave function |
|||
Maximum cable length per segment |
Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M |
||
Maximum number of stations |
Each segment with 32 stations and each network with 126 stations |
||
Point to point (PPI main station mode) |
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time |
||
MPI connection |
A MPI slave station can connect up to 8 MPI masters |
||
Isolation |
Communication port isolation |
||
RJ45 port |
|||
Communication protocol |
H35-00 |
H36-00/H36-01 |
H36-01 |
PPI/MPI, free port (Modbus RTU) |
EtherCAT |
CANopen |
|
Communication baud rate |
PPI/MPI:9.6Kbps,19.2Kbps,187.5Kbps |
100Mbps |
20Kbps~1Mbps |
Free port:1.2Kbps~115.2Kbps |
|||
Maximum cable length per segment |
Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M |
100m connection |
Maximum 2500 m (20Kbps) Minimum 25m (1Mbps) Refer to CANopen communication port
|
Maximum number of stations |
Each segment with 32 stations and each network with 126 stations |
No limit |
Each master station support a maximum of 32 slaves |
Point to point (PPI main station mode) |
Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time |
-- |
-- |
MPI connection |
A MPI slave station can connect up to 8 MPI masters |
-- |
-- |
Isolation |
Communication port isolation |
||
EtherNET port |
|||
Communication port |
1*EtherNET port |
||
Baud rate |
10/100Mbps adaptive |
||
Protocol types |
Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU |
||
Maximum length of each cable |
100m directly connected |
||
Maximum number of connections per site |
UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP |
||
Quantity of user data |
Up to 200 bytes for UDP_PPI transfer, Up to 240 bytes for ModBus_TCP transmission, A maximum of 512 bytes are used for Socket transmission
|
||
DHCP function |
Support | ||
Remote monitoring/programming |
Support | ||
Isolation |
Communication port isolation |
CANopen port |
||||||||
Communication port |
-- |
1*CAN port |
||||||
Maximum number of slave stations |
1 master station can be connected maximum of 32 slave stations |
|||||||
Protocol types |
CANopen DS301standard protocol |
|||||||
Support functions |
Supports automatic starting of CANopen Manager |
|||||||
Supports optional slave polling |
||||||||
Support to start slave stations |
||||||||
Support NMT |
||||||||
Support synchronous production |
||||||||
Support synchronous consumption |
||||||||
Support heartbeat generation |
||||||||
Support activation time creation |
||||||||
Transmission rate(kbit/s) |
1000 |
800 |
500 |
250 |
125 |
50 |
20 |
|
Maximum length(m) |
25 |
50 |
100 |
250 |
500 |
1000 |
2500 |
|
Isolation |
Communication port isolation |
Power interface definition
4pin terminals spaced at 3.81mm apart |
Symbol |
Signal definition |
|
L+ |
+24V power |
M |
+24V power ground |
|
|
Ground |
|
-- |
-- |
USB interface definition
USB port |
No. |
Signal |
Signal definition |
1 |
V_BUS |
+5V power |
|
2 |
Data- |
Data- |
|
3 |
Data+ |
Data+ |
|
4 |
GND |
Ground |
EtherNET interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
TX+ |
Positive end of data transmission |
2 |
TX- |
Negative end of data transmission |
|
3 |
RX+ |
Positive end of data transmission |
|
4 |
TERM |
-- |
|
5 |
TERM |
-- |
|
6 |
RX- |
Negative end of data transmission |
|
7 |
TERM |
-- |
|
8 |
TERM |
-- |
|
Shell |
PE |
Shell ground |
|
Green indicator |
As an indication of EtherNET connection status |
||
Yellow indicator |
As an indication of EtherNET connection status |
CAN interface definition
RJ45 port |
No. |
Signal |
Signal definition |
1 |
CAN_H |
Positive end of data transmission | |
2 |
CAN_L |
Negative end of data transmission | |
3 |
-- |
-- |
|
4 |
-- |
-- |
|
5 |
-- |
-- |
|
6 |
-- |
-- |
|
7 |
CAN_GND |
CAN Gound |
|
8 |
-- |
-- |
|
Shell |
PE |
Shell ground | |
Green indicator |
As an indication of CAN connection status |
||
Yellow indicator |
As an indication of CAN connection status |
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart |
||
6pin terminals |
Signal |
Signal definition |
|
A0 |
PORT0 RS485 signal A |
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
|
A0 |
PORT0 RS485 signal A |
|
B0 |
PORT0 RS485 signal B |
|
SG |
PORT0 RS485 signal ground |
Dial switch definition
Dial switch |
Symbol |
Dial direction |
Signal definition |
RUN |
Up |
System operation |
|
STOP |
Down |
System halt |
|
Swivel 5 times in 3 seconds |
Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
DIP dial |
No. |
Symbol |
Signal definition |
Note |
|
1 |
Term-PORT0 |
Terminal resistance switch 1(PORT0) |
ON:with terminal resistance OFF:without terminal resistance |
2 |
Term-PORT1 (H35-00) |
Terminal resistance switch 2(PORT1) |
ON:with terminal resistance OFF:without terminal resistance |
|
NC (H36-00/H36-01) |
-- |
-- |
||
3 |
RMC-SW |
Remote control switch |
ON:Remote control allow OFF:Remote control forbid |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.