Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust

Product Details
Customization: Available
Task: Program
Structure: Combination
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
>2000 square meters
  • Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
  • Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
  • Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
Find Similar Products
  • Overview
  • Product Description
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTH3 PNT-000S1
Signal
Continuous
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Weight
0.35kg
Module Category
Communication Module
Communication Protocol
Profinet
Maximum Number of Modules Supported Per
8
Transport Package
CTN
Specification
34*115*100mm
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

 

Product Description
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust

Order No.: CTH3 PNT-000S1
Specification: PROFINET slave module, can be extended up to 8 modules(CAN and ECT is not included)


1. The PROFINET bus communicates at a rate of 100 Mb Ps, and the communication distance from station to station can be up to 100 meters (100BASE-TX);

2, topological structure support star, tree, linear, ring structure;

3. Each slave station is allowed to expand 8 I/O modules (digital quantity module, analog quantity module, temperature module, HSC, HSP, excluding CAN module /ECT slave station module).

4. Supported Siemens PROFINET master station, including Siemens S7-300, Siemens S7-400, Siemens S7-1200, Siemens S7-1500;

5. Configuration software TIA Portal V13 and higher.

 

Physical properties

Size(W×H×D)

34×115×100mm mm

Power loss

Rated input voltage

24V DC

Input voltage range

20.4V~28.8V DC

Input current

0.8A

Bus power supply voltage

+5V DC

Bus supply current

1.6A

Isolation

External power supply is isolated from system power supply

Power protection

The power supply end provides the reverse connection protection function and the surge absorption function

LED indicator characteristics

24V power indicator (green)

ON = 24VDC power supply is normal

OFF = No 24VDC power supply

SF indicator light (red)

ON = extended I/O bus failure or PROFINET module failure

OFF = No error 

BF indicator light (red)

ON = PROFINET bus communication failure (no connection to switch, no network detected)

Blinking=Inconsistent hardware configuration

OFF = No error 

MT indicator light (yellow)(Maintenance indicator light)

 

Reserved

Indicator light (green)

ON = There is a connection to the switch /PN master

OFF =No connection to switch /PN master

Indicator light (yellow)

ON = data receiving and receiving to switch /PN master station

OFF = No data transceiver to switch /PN master station

EetendI /O capabilities

Maximum number of modules supported per slave

8(can be added digital , analog and temperature module, HSC,HSP module, other types of module are not included)

Protocol type

CTH300 PLC custom 55MHz bus protocol

Topology

Support star, tree, linear, ring

PROFINET communication port

Communication port

1 dual RJ45 port

Data transmission rate

Ethernet with a transmission rate of 10Mbps

The PROFINET transmission rate is 100Mbps, full duplex

Supported Ethernet services

Ping, ARP, Network Diagnostic (SNMP)/MIB-2, LLDP

Sending cycle

250us~4ms

Third-party PROFINET master station

Support

Longest communication distance from station to station

100m(100BASE-TX)

Topology

Supports star, tree, linear and ring topologies

Isolation

Communication port isolation

Hardware configuration function

Import file type

Profinet GDS file XML format

Third-party PN master station

The addition of the CTH3 PNT-000S1 module supports the expansion of 8 slots

Expansion module can add digital, analog and temperature module, HSC,HSP module, other types of module are not included

 
Certifications
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
 
Company Profile
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, CotrustCth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
Cth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, CotrustCth3 Pnt-000s1, Cth300 Series Profinet Slave Station Module, Expandable up to 8 Cth300 Series Io Modules, Cotrust
FAQ

Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.

 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier