• Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
  • Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
  • Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
  • Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
  • Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
  • Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

Task: Program
Structure: Combination
Signal: Continuous
Function: Automatic Control
Certification: RoHS, ISO: 9001, CE
Condition: New
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Our Advantages
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTS7-231-7PD32/CTS7-231-7PF32/CTS7-231-7PF3A
Customized
Customized
Weight
0.15kg
Input Number of Points
4ai/8ai
Input Type
Thermocouple(Tc)
Power Dissipation
1.7W
Transport Package
CTN
Specification
71*80*62mm
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

 
Product Description
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

Order No.: CTS7 231-7PD32
Specification: TrustPLC CTSC-200 EM231 thermal resistance input module, 4AI×TC, J/K/R/S/T/E/N, 16BIT isolated
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

Order No.: CTS7 231-7PF32/CTS7 231-7PF3A
Specification: TrustPLC CTSC-200 EM231 thermal resistance input module, 8AI×TC, J/K/R/S/T/E/N, 16BIT isolated
 
Our Advantages
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

CTSC-200 series is a new generation of high-performance PLC with high cost-effective,excellent performance,multi-protocol communication ports and a abundant instruction,which can apply to various of industries and adapt to the complex control requirements of small and medium control system.

Powerful communication capability

Ethernet communication mode:10/100Mbps Ethernet support MODBUS_TCP and UDP_PP protocol.Multiple host networking communication in the LAN, to programming, debugging and remote monitoring in the WAN.

PPI communication mode:CTSC-200 series CPU integrated 1-2 PPI port which hardware interface is the RS485 or RS232,provide communication rate 9.6Kbps,19.2Kbps,187.5Kbps,PPI is token-ring network structure,can form PPI network without relay,to complete data exchange through NETR and NETW,each exchange package can be up to 200bytes,each CPU can connect eight modules,that is each CPU can connect to 8 PC or other CPU.

If the I/O of some system is relatively too large that one CPU can not meet requirement,can achieve by several CPU,multi-CPU structure can achieve distributed control thant with high sstem reliability.The data exchange is extremely fast and convenient because of the powerful communication capability among different CPUs.

MPI communication mode:CTSC-200 series CPU can connect to the MPI network,communication rate 19.2Kbps,187.5Kbps which only work as slave station in the MPI network.The different slave stations can not communication each other while the master stations can read the data of slave station.

Profibus-Dp or Ethernet communication mode:CPU can be connected to the Profibus field by by DP slave stations,as salve station of certain master station,it can exchange data fast and real-time also can run independently which with high reliability.

CPU can be connected with industrial Ethernet by Ethernet module which is suitable for building control or other applications with several stations.

CANopen communication mode:To form network through CAN communication,each CAN master station can connect 32 CAN slave stations or devices,baud rate up to 1MBit/s within 25m,baud rate up to 20MBit/s within 2500m.

Freeport communication mode:CPUs provide 1-2 freeport,embedded several free communication protocol library such as Modbus,USS etc.

CPU 226L,CPU226H with two freeport can communicate simultaneously so as to meet the requirements of such occasions like high-speed communication ,synchronous control,many peripherals.

Performance Parameters

Specification

 EM231, 4AI×TC

 EM231, 8AI×TC

Physical Features

   Dimensions(W×H×D)

71×80×62mm

71×80×62mm

   Power Loss(dissipation)

1.7W

1.7W
Power Consumption
    From +5V(from I/O bus)

87mA

    From L+ 60 mA
    L+  voltage range,class  2 or DC sensor supply 20.4~28.8V DC
    LED indicator 24 VDC Power Supply  Good: ON = no fault,OFF = no power ;
           SF: ON=module fault, Blink=input signal error, OFF=normal;
Analog Input Features
   Input type Floating Thermocouple
   Input range TC type(select one per module):    S, T, R, E, N, K, J
           Voltage range: +/-80mV
   Number of analog input points 4 points 8 points
Isolation

    Field to Logic

    Field to 24V DC
    24V DC to logic

500V AC
500V AC
500V AC

    Common mode input range
               (input channel to input channel)

120V AC

    Common mode rejection    

>120dB@120V AC

Input resolution

    Temperature

    Voltage

0.1ºC/0.1ºF 
 15 bits plus sign

Measuring principle

Sigma-Delta
Module update time for all channel 425ms 825ms
wire length to sensor, maximum 100 m
Wire loop resistance 100Ω
Suppression of interference 85dB@ 50Hz/60Hz/400Hz
Data word format Voltage: -27648 to +27648
Input impedance ≥1MΩ
Maximum input voltage 30V DC
Input filter attenuation -3dB@ 21kHz
Basic error 0.1% FS(Voltage)
Repeatability 0.05% FS

Cold junction error

±1.5ºC
24V DC supply voltage range 20.4 to 28.8 VDC
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)

Thermal resistance modules diagnostic

Error type Channel data SF LED 24V LED Range status bit 24V power failure
No module power 32766 OFF OFF 0 1
Offline 32767(positive calibration) -32768(negative calibration) BLINK ON 1 0
Temperature out of range 32767(positive calibration)
-32768(negative calibration)
BLINK ON 1 0
DIP switch configuration
The EM231 module provides a convenient and isolated interface for the seven thermocouple types: J, K, E, N, S, T, and R. It also allows to connect tiny analog signals (±80mV). All thermocouples connected to the modules must be the same type, and it is best to use a shielded thermocouple sensor.
Thermocouple modules use DIP switch to select the thermocouple type, disconnect check, measurement unit, cold end compensation and open fault direction.
For the EM231 4TC module, SW1 ~ SW3 is used to select the thermocouple type, SW4 is not used (set to the OFF position), SW5 is used to select the direction of wire breaking detection, SW6 is used to select whether to conduct wire breaking detection, SW7 is used to select the measuring unit, and SW8 is used to select whether to conduct cold end compensation.
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)For the EM231 8TC module, SW1 ~ SW3 is used to select the thermocouple type, SW4 is used to select the direction of wire breaking detection, SW5 is used to select the measuring unit, SW6 is used to select whether to conduct cold end compensation. wire breaking detection is fixed to be yes, no need to set.
Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)In order for the DIP switch setting to work, you need to Power off then on for the PLC or the 24VDC.
Type of thermal resistance configuration
Type SW1 SW2 SW3
J (default) 0 0 0
K 0 0 1
T 0 1 0
E 0 1 1
R 1 0 0
S 1 0 1
N 1 1 0
+/- 80mV 1 1 1
Other specifications
Items EM231 4TC EM231 8TC
Switch setting Switch setting
breaking detection direction SW5 0: positive(+3276.7° )
1: negative (-3276.8° )
SW4 0: positive(+3276.7° )
1: negative (-3276.8° )
Whether detect breaking SW6 0: yes, 1: no Fixed for breaking detection
Select measuring unit SW7 0: ºC, 1: ºF SW5 0: ºC, 1: ºF
Whether CJC SW8 0: yes, 1: no SW6 0: yes, 1: no
Software Configuration(231-7PF32)
For EM231 8AI×16 bits, reading in VW instead of AIW. The relative location of the module is different, so is the corresponding address. Calculation formula:
x(VWx) = slot no. × 64 + input channel × 2
The slot number of the address quick reference table corresponds to the installation location of the module. The first expansion module close to the CPU has the slot number of 0, the second expansion module has the slot number of 1, and so on. There are 8 input channels, from A to G, and the corresponding number is 0 to 7.
 Quick reference of address based on formula above:
VWxx channel 0 channel 1 channel 2 channel 3 channel 4 channel 5 channel 6 channel 7
slot 0 VW0 VW2 VW4 VW6 VW8 VW10 VW12 VW14
slot 1 VW64 VW66 VW68 VW70 VW72 VW74 VW76 VW78
slot 2 VW128 VW130 VW132 VW134 VW136 VW138 VW140 VW142
slot 3 VW192 VW194 VW196 VW198 VW200 VW202 VW204 VW206
slot 4 VW256 VW258 VW260 VW262 VW264 VW266 VW268 VW270
slot 5 VW320 VW322 VW324 VW326 VW328 VW330 VW332 VW334
slot 6 VW384 VW386 VW388 VW390 VW392 VW394 VW396 VW398
 231-7PF3A and 231-7PD32 is is AIW addressing
Company Profile

Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)Cotrust Em231 Thermocouple Module PLC Logic Controller Compatible Siemens (231-7pd32/231-7PF32/231-7PF3A)
FAQ
 

Q1.What's the payment term? 
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now