Order No.:CTH3 C35-003S2
Specification: 32MB program data space,64KB power-off hold data,55M expansion bus,24VDC power supply,2*RS485 port,1*EtherNET port,1*USB port,,1*CAN port,1 *EtherNET/EtherCAT port; Maximum number of racks :4 (including local racks) Support up to 128 EtherCAT slave stations and support CODESYS programming platform SP18 version.
Specification parameter |
Order number |
Basic model,32MB program data space,64KB power down hold data,55M expansion bus,24VDC power supply, 2*RS485 ports,1*EtherNET port,1*USB port,1*CAN port,1*EtherNET/EtherCAT port: supports visual WebVisu and OPC UA slave station, support EtherNet/IP master station, support MODBUS(RTU/TCP) master/slave, support single-axis motion,Maximum number of racks:4 (including local racks),support up to 128 EtherCAT slave stations, support CODESYS programming platform SP18 version. |
CTH3 C35-003S2 |
Product model |
C35-03 | ||||||||
Order numbe |
CTH3 C35-003S2 | ||||||||
Physical characteristics |
|||||||||
Size (WxHxD) |
34×115×101.6 mm | ||||||||
Power loss |
19.2W | ||||||||
Power supply characteristic |
|||||||||
Rated input voltage |
24V DC | ||||||||
Input voltage range |
20.4V~28.8V DC | ||||||||
Input current |
0.8A | ||||||||
Polarity reverse protection |
Yes | ||||||||
Bus power voltage |
+5V DC | ||||||||
Bus power current |
1.6A | ||||||||
LED indicator characteristics |
|||||||||
24V Power indicator (green) |
On: 24VDC power supply is normal; Off: No 24VDC power supply. |
||||||||
SF Indicator (red) |
On: The system is faulty. Off: no error. |
||||||||
BF indicator (red) |
On: The bus is faulty. Off: no error. |
||||||||
RUN indicator (green) |
On: The system is running. OFF: The system stops |
||||||||
STOP indicator (yellow |
On: The system stops. Off: The system is running |
||||||||
Ethernet indicator |
(Green) |
On: Connect; Off: No connection |
|||||||
(Yellow) |
On: 100Mbps; Off: 10Mbp |
||||||||
CAN port indicator |
(Green) |
On: Connected; Off: Not connected |
|||||||
(Yellow) |
On: 100Mbps; Off: 10Mbps |
||||||||
Instruction performance |
|||||||||
Bit instruction execution speed |
15ns | ||||||||
Floating point instruction execution speed |
45ns | ||||||||
Internal memory |
|||||||||
User program space |
32M | ||||||||
Power off hold space |
64KB | ||||||||
Data storage specification |
Zone I 32K, Zone Q 32K, zone M 512K |
||||||||
Integrated communication function |
|||||||||
Bus interface |
Support |
||||||||
USB port |
1 | ||||||||
EtherNET port |
2(One of them is an EtherNET/EtherCAT switchable communication interface) |
||||||||
RS485 port | 2 | ||||||||
EtherCAT port | 1 | ||||||||
CAN port | 1 | ||||||||
EtherCAT port | |||||||||
Communication interface |
1*EtherCAT por |
||||||||
Baud rate |
100Mbps adaptive |
||||||||
Protocol type |
EtherCAT Interface protocol |
||||||||
Maximum cable length per section |
100m | ||||||||
Maximum number of sites |
Each master supports a maximum of 128 EtherCAT slave stations |
||||||||
Support function |
Support distributed clock configuration, redundancy Settings |
||||||||
Support startup parameter configuration |
|||||||||
Support PDO parameter configuration and mapping |
|||||||||
Support for bus cycle configuration, configure startup check vendor ID and product ID | |||||||||
Isolate |
Yes | ||||||||
RS485 communication port |
|||||||||
Number of communication interfaces |
2,PORT0,PORT1 |
||||||||
Communication protocol |
Free port protocol (built-in MODbus-RTU protocol) |
||||||||
Free port baud rate |
Ranges from 1.2Kbps to 115.2Kbps |
||||||||
Maximum cable length per section |
Use isolation repeater: 1000m(115.2Kbps) 1200m(38.4 kbps) Isolation repeater not used: 50m |
||||||||
Maximum number of sites |
32 stations per segment, 126 stations per network. |
||||||||
Isolate |
Communication port isolation |
||||||||
CANopen port | |||||||||
Communication interface |
CANopen | ||||||||
Maximum number of secondary sites |
32 | ||||||||
Protocol typ |
CANopen DS301 standard protocol |
||||||||
Support function |
Support automatic start CANopen Manager |
||||||||
Support Optional slave polling | |||||||||
Support starting the slave station | |||||||||
Support NMT | |||||||||
Support synchronous production | |||||||||
Support synchronous consumption | |||||||||
Support heartbeat generation | |||||||||
Support activation time creation | |||||||||
Transmission rate (kbit/s) |
1000 | 800 | 500 | 250 | 125 | 50 | 20 | ||
Maximum length (m) |
25 | 50 | 100 | 250 | 500 | 1000 | 2500 | ||
Isolate |
Communication port isolation | ||||||||
EtherNET port | |||||||||
Communication interface |
2*EtherNET ports (one of which is EtherNET/EtherCAT for switching communication) |
||||||||
Baud rate |
10/100Mbps adaptive |
||||||||
Protocol typ |
CODESYS custom protocol, based on UDP and TCP(Ethernet programming and CPU support |
||||||||
Maximum cable length per section |
100m | ||||||||
Maximum number of connections for a site |
UDP supports a maximum of 16 connections | ||||||||
Isolat |
Communication port isolation |
||||||||
Programming Software |
|||||||||
Programming package |
CODESYS V3.5 (SP18 version) |
||||||||
Programming language |
Programming language according to IEC61131-3: CFC/FBD/LD/IL/ST/SFC |
||||||||
Protection function |
|||||||||
Power supply protection |
The power supply terminal provides reverse protection and surge absorption functions |
||||||||
Interface protection |
Lightning protection for communication ports |
||||||||
Local I/O scalability |
|||||||||
Maximum number of racks |
4 | ||||||||
Maximum number of modules |
Host rack: 11 (power module, CPU, trunk module, 8 signal modules) Slave rack: 10 (power module, trunk module, 8 signal modules) |
||||||||
Remote I/O expansion capability |
|||||||||
CAN extended maximum number of master stations |
1 | ||||||||
CAN maximum number of slave stations |
Each master station connects to a maximum of 32 CAN slave stations. |
||||||||
EtherCAT maximum number of extended slaves |
Up to 128 EtherCAT slave modules , each EtherCAT slave module has a maximum of 8 signal modules | ||||||||
Supports motion control function |
|||||||||
Motion control function |
Do not support SoftMotion and CNC |
||||||||
Real-time clock |
|||||||||
Power off hold |
The power failure holding time is about 112 hours (typical value), and the power failure holding time can reach at least 1 year after the external battery is connected | ||||||||
Precision |
Monthly deviation <60 seconds |
Power interface definition
4-pin removable terminals with 3.81mm spacing |
Symbol |
Signal definition |
|
L+ |
+24V power supply |
M |
+24V power ground |
|
|
Earth |
|
-- |
-- |
USB interface definition
USB interface |
Bit number |
Signal |
Signal definition |
|
1 |
V_BUS |
+5V power supply |
2 |
Data- |
Data- |
|
3 |
Data+ |
Data+ |
|
4 |
GND |
Earth |
EtherNET/EtherCAT interface definition
RJ45 network port |
Bit number |
Signal |
Signal definition |
|
1 |
TX+ |
Data sending end |
2 |
TX- |
Data sending negative end |
|
3 |
RX+ |
Data receiving terminal |
|
4 |
TERM |
-- |
|
5 |
TERM |
-- |
|
6 |
RX- |
Data receiving negative end |
|
7 |
TERM |
-- |
|
8 |
TERM |
-- |
|
Connector housing |
PE |
Casing grounding
|
|
Green lindicator |
As an indication of EtherNET/EtherCAT connection status |
||
Yellow indicator |
As an indication of EtherNET/EtherCAT speed status |
CAN interface definition
RJ45 network port |
Bit number |
Signal |
Signal definition |
1 |
CAN_H |
Data sending end |
|
2 |
CAN_L |
Data sending negative end |
|
3 |
-- |
-- |
|
4 |
-- |
-- |
|
5 |
-- |
-- |
|
6 |
-- |
-- |
|
7 |
CAN_GND |
CAN_GND |
|
8 |
-- |
-- |
|
Connector housing |
PE |
Casing grounding |
|
Green lindicator |
As an indication of the status of CAN data reception |
||
Yellow indicator |
As an indication of the status of CAN data transmission |
RS485 interface Definition
The Port0 port uses two detachable terminals with a 3-pin spacing of 3.81mm |
||
6-bit detachable terminal |
Signal
|
Signal definition |
|
A0 |
PORT0 port RS485 signal A |
B0 |
PORT0 port RS485 signal B |
|
SG |
PORT0 port RS485 signal GND |
|
A0 |
PORT0 port RS485 signal A |
|
B0 |
PORT0 port RS485 signal B |
|
SG |
PORT0 port RS485 signal GND |
Dip switch definition
Two-state switch |
Bit number |
Dip direction
|
Signal definition
|
|
ON |
UP |
System operation |
OFF |
Down |
System stop |
|
DIP switch |
Bit number |
Symbol
|
Signal definition
|
|
1 |
Term-PORT0 |
Terminal Resistance Switch 1 (PORT0) ON: terminal resistance; OFF: no terminal resistor |
2 |
NC |
Reserve |
|
3 |
NC |
Reserve |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.