| Model | CTSI-H312-16N1 | |
| Power Supply Specifications | ||
| Rated Input Voltage | 24V DC(20.4V~28.8V) | |
| Rated Input Current | 1A | |
| Input Power Protection | Supports polarity reverse connection protection | |
| Local Hardware Specifications | ||
| Dimensions(W×H×D) | 53×104×80 mm | |
| Digital Inputs | 8DI | |
| Digital Outputs | 8DO | |
| Bus Interface | 1 | |
| Ethernet | 1 | |
| EtherCAT | 1 | |
| RS485 | Supports up to 5 channels (1 on main unit, 2 via expansion cards) | |
| TypeC | 1 | |
| Expansion Card Slots | 2 | |
| Memory Specifications | ||
| Program Capacity | 256K Byte | |
| Data Capacity | 1M Byte(DB can address 1M data space) | |
| Non-volatile Memory Space | 160K Byte(V:64KB,M:64KB,DB:32KB) | |
| Program Organization Units | Max. 1024 OB+FC+FB, each block up to 64KB | |
| Expansion Capabilities | ||
| Expansion Modules | 16 (All simple series modules expandable from main unit) | |
| Expansion Cards | Supports analog, CAN, RTC, serial port | |
| Programming Software Specifications | ||
| Software Version | MagicWorks PLC (V2.32 or above) | |
| Programming Languages | LAD/STL/C language | |
| Instruction Cycle | ||
| Logic Instructions | 0.086us | |
| Floating-point Instructions | 1.4us | |
| Motion Control | ||
| EtherCAT Axes | 16 | |
| Axis Control Capability | 4 Axes/1ms | |
| Pulse Axes | 4 | |
| Input Specifications - Hardware Parameters | ||
| Number of Input Points | 8 | |
| Input Type | Sinking/Sourcing | |
| Rated Load Input Voltage | 24V DC( 20.4V~28.8V DC ) | |
| Maximum Load Cable Length | Shielded - 500m (Standard Input), 50m (High-Speed Counter Input) Unshielded - 300m (Standard Input) |
|
| Logic 1 (Min) | 15V DC,>2.5mA | |
| Logic 0 (Max) | 5V DC,<1mA | |
| Input Filter | Configurable; supports 0.2μs, 0.4μs, 0.8μs, 1.6μs, 3.2μs, 6.4μs, 12.8μs, 0.2ms, 0.4ms, 0.8ms, 1.6ms, 3.2ms, 6.4ms, 12.8ms; default is 6.4ms | |
| Software Function | Supports hardware reconfiguration in the program without modifying the software logic when a point is damaged. | |
| Protection Function | Surge Voltage -35V DC, lasting 0.5s | |
| Maximum Allowed Leakage Current | 1mA | |
| Isolation | 500V AC,1 minute | |
| Input Specifications - HSC Parameters | ||
| Number of Input Channels | 4 | |
| Single-Phase Counter | 4×200KHz | |
| Two-Phase Counter | 4×100KHz | |
| Function Description | Supports arbitrary modification of points and internal pulse capture. | |
| Output Specifications - Hardware Parameters | ||
| Number of Output Points | 8 | |
| Output Type | Transistor Sinking Output | |
| Rated Output Voltage | 24V DC(20.4~28.8V DC) | |
| Rated Output Current | 0.5A | |
| Output Load | Resistive Load - 0.5A per point, 2A for 8 points Inductive Load - 7.2W per point, 24W for 8 points Lighting Load - 5W per point, 18W for 8 points |
|
| Output Frequency | Resistive Load - 200KHz Inductive Load - 0.5Hz Lighting Load - 10Hz |
|
| Off to On (Delay) On to Off (Delay) |
<0.2us <2us |
|
| Maximum Residual Voltage (ON) Leakage Current (OFF) |
<0.5V DC <30uA |
|
| Maximum Load Cable Length | Shielded - 500m Unshielded - 150m |
|
| Software Function | Supports hardware reconfiguration in the program without modifying the software logic when a point is damaged. | |
| Protection Function | Short-circuit protection, overcurrent protection | |
| Isolation | 500V AC,1 minute | |
| Output Specifications - HSP Parameters | ||
| Number of Output Channels | 4 (Pulse/Direction) | |
| Output Frequency | 200KHz | |
| Function Description | Supports arbitrary modification of points and group pulse axes; supports pulse/direction output delay and optional direction. | |
| Output Specifications - PWM Parameters | ||
| Number of Output Channels | 4 | |
| Output Frequency | 10Hz~20KHz | |
| Period | 50~100000us | |
| Duty Cycle | 0.00~1.00 (2 decimal places) | |
| Function Execution Result | Duty Cycle Result 1 100% duty cycle, continuous ON output 0 0% duty cycle, continuous OFF output |
|
| Communication Interface - Ethernet | ||
| Number of Interfaces | 1 | |
| Baud Rate | 10/100Mbps Auto-Negotiation | |
| Supported Protocol Types | UDP_PPI Protocol Modbus TCP/IP Master/Slave Protocol S7 Master/Slave Protocol CTNET Socket PN Slave Function OPC UA MQTT |
|
| Protocol Support Quantity | Total connections ≤ 64 UDP_PPI: Max 8 connections Modbus TCP/IP Master/Slave: Supports data reading from up to 32 slaves; default Ethernet port is slave S7 Master/Slave: 8 connections, no master/slave distinction CTNET: Supports 64 slaves Socket: Supports 32 UDP and 32 TCP connections |
|
| Protocol Corresponding Data Transmission Size | UDP_PPI: 200 bytes Modbus TCP/IP: Only one data transmission at a time, 240 bytes S7 Master: 200 bytes CTNET: Master supports 64K slave data reading; slave supports 10K data transparent transmission Socket: 512 bytes |
|
| Local Monitoring/Local Programming Function | Supported | |
| Remote Monitoring/Remote Programming Function | Supported | |
| Maximum Cable Length per Segment | 100m | |
| Isolation | Communication port isolation | |
| Software Function | Supports switch functionality with EtherCAT | |
| Communication Interface - EtherCAT | ||
| Number of Interfaces | 1 | |
| Baud Rate | 100Mbps | |
| Maximum Cable Length per Segment | 100m | |
| Number of Slaves | 72 | |
| Supported Functions | Supports distributed clock configuration Supports startup parameter configuration Supports PDO parameter configuration and mapping Supports configuration of bus cycle period Supports startup check for vendor ID and product ID Supports slave scanning Supports slave station masking |
|
| Communication Interface--RS485 | ||
| Number of Interfaces | Supports up to 5 channels (1 on main unit, 2 expandable via expansion cards) | |
| PPI Baud Rate | 9.6Kbps,19.2Kbps,187.5Kbps | |
| Free Baud Rate | 1.2Kbps~115.2Kbps; built-in Modbus RTU master/slave functionality | |
| Maximum Cable Length per Segment | With isolated repeater: 1000m (187.5Kbps), 1200m (38.4Kbps) Without isolated repeater: 50m |
|
| Isolation | Communication port isolation | |
| Number of Slaves per Channel | 32 stations per segment MPI connection: one MPI slave can connect to up to 8 MPI masters Point-to-point (PPI master mode, NETR/NETW): each instruction reads/writes up to 200 bytes, with up to 8 read/write instructions allowed simultaneously |
|
| Hardware Interface--TypeC | ||
| Supported Functions | Updates programs and firmware via USB flash drive Directly downloads and updates programs via TYPE-C interface Supports power supply through TYPE-C interface |
|
| Hardware Interface - Expansion Card Slot Supported Models CTSI-485/48 |
||
| CTSI-485/485/RTC-E1 | Two of this type can be expanded, regardless of slot Each card can expand 2 additional RS485 interfaces, supports free protocol, and Modbus RTU master/slave functionality |
|
| CTSI-485/CAN-E1 | One of this type can be expanded, regardless of slot Expands 1 RS485 interface, supports free protocol and Modbus RTU master/slave Expands 1 CAN interface, supports Canopen master protocol (expandable to 32 slaves) and CANFree protocol |
|
| CTSI-AMS03-E2 | Two of this type can be expanded, regardless of slot Each card can expand 2AI*12bit, 1AQ*12bit |
|
| CTSI-RTC-E1 | One of this type can be expanded, regardless of slot Expands RTC clock, clock accuracy: ±120 seconds/month |
|
| LED Indicator Characteristics | ||
| PWR Indicator | Green | ON = 24VDC power supply normal, OFF = No 24VDC power supply |
| SF Indicator | Red | ON = System fault, OFF = No fault |
| BF Indicator | Red | ON = Bus fault, OFF = No fault |
| RMC Indicator | Green | ON: CPU and remote server communication successful (EtherNET communication port parameters correctly configured) |
| OFF: CPU and remote server communication failed or prohibited | ||
| RUN Dual-Color Indicator | Green | ON = System running, OFF = System stopped |
| Yellow | ON = System stopped, OFF = System running | |
| RJ45 Indicator | Green | ON = Connected, OFF = Not connected |
| Yellow | ON = 100Mbps,OFF = 10Mbps | |
| Digital Input Indicator | Green | ON = Signal input, OFF = No signal input |
| Digital Output Indicator | Green | ON = Signal output, OFF = No signal output |
| PB Indicator | Green | ON = Expansion bus power supply normal, OFF = No expansion bus power supply |
| Power-On Indicator Status | Before CPU operation: PWR light on, others (SF, BF, RMC, RUN) off | |
| After CPU operation: PWR light on, RUN green light on, others (SF, BF, RMC, RUN yellow) off | ||







Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.