• Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
  • Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC

Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC

Task: Program
Structure: Combination
Signal: Continuous
Function: Automatic Control
Certification: RoHS, ISO: 9001, CE
Condition: New
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTH2 277-0PN36
Customized
Customized
Weight
0.2kg
Communication Rate
100Mbps
Topological Structure
Star Shaped, Tree Shaped, Linear, Circular
Maximum Number of Expansion I/O
8
Real Time Performance
Only Supported Rt, with a Minimum Cycle of 1ms
Transport Package
CTN
Specification
71*80*62mm
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

Product Description
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC

Order No.: CTH2 277-0PN36
Specification: Profinet slave module, only supports RT real-time communication mode, can expand up to 8 CTH200 series IO modules (excluding CAN module, operation control module, weighing and other special modules)
 

1,Profinet bus communication rate 100Mbps,the maximum communication distance up to 100m between two slave module(100BASE-TX).

2,The topological structure support star,tree,linear,ring structure.

3,Each slave module allow to extend 8 I/O module(digital module,analog module,temperature module,PID module.but CAN module,motion control module,weighting  module are not include).

4,Support Siemens Profinet master station,Siemens Smart200,Siemens S7-300,Siemens S7-1200,Siemens S7-1500.Support  Modbus RTU,PPI,Mitsubishi,Omron,Delta protocol.

5,Programming software TIA Portal V13 and above version.

Profinet architecture diagram
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
Performance Parameters
 

Physical Features

Dimension(W×H×D)

71×80×62 mm

Power Consumption

Rated voltage input

24V DC

Voltage range

20.4V~28.8V DC

Current input

0.8A

Bus power voltage

+5V DC

Bus power current

1.1A

Isolation

The external power supply is isolated from the system power supply

Power protection

provides reverse connection protection and surge absorption

LED Indicator

24V Indicator(Green)

ON = 24VDC power

OFF = 24VDC no power

SF Indicator(red)

ON = extend I/O Bus failure or PROFINET module failure

OFF = no fault

BF Indicator(red)

ON = PROFINET Bus communication failure (no connection to switch, no network detected)

Blinking=Hardware configuration is inconsistent

OFF = no fault

MT Indicator(yellow)

(maintenance indicator )

ON = Loss of synchronization

OFF =  no fault

P1R/P2Rport Indicator(green)

ON = There is a connection to the switch /PN master station

OFF = There is no a connection to the switch /PN master station

P1R/P2RportIndicator(yellow)

ON = received data

OFF = no received data

Expansion I/O

Maximum support module

8(digital module,analog module,temperature module and PID module,other moudle is not included)

Protocol

CTH200 PLC 4MHZ Bus protocol

Maximum  IO each station

Analog IO up to 64AI/32AQ

Digital IO up to 256DI/256DQ

Topological structure

support star,tree,linear,ring structure.

PROFINET port

Communication port

1*dual RJ45 port

Data transmission rate

Ethernet speed rate 10Mbps

PROFINET speed rate100Mbps

Support Ethernet

ping,arp,(SNMP)/MIB-2,LLDP

Real time performance RT: Supported, minimum cycle 1ms, not IRT supported

The third partPROFINET master station

Support

Maximum distance

100m(100BASE-TX)

Topological structure

support star,tree,linear,ring structure.

Isolation

Communication port isolation

Hardware configuration function

File type

PROFINET GDS file XML format

The third partPN master station

Add CTH 277-0PN32 then support 8pcs expansion model

digital module,analog module,temperature moduleand PID module,other moudle is not included


External Power Interface Definition
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
RJ45 Network Port Definition
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
Installation specifications
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCInstallation method 
When installing and disassembling the CTS7/CTH2 277-0PN36 module, appropriate safety measures must be taken in advance and the power supply to the CTS7/CTH2 277-0PN36 module must be confirmed to be cut off. 
The CTS7/CTH2 277-0PN36 module can be installed on both the control cabinet backplane and standard DIN rails; It can be installed horizontally or vertically. 
Installing panels 
1) Position and drill holes according to the size requirements in Figure 4-6; 
2) Secure the module to the backplane with appropriate screws; 
3) If an expansion module is used, connect the flat cable of the expansion module to the expansion port under the front cover. 
DIN rail installation 
1) Fix the guide rail on the back panel; 
2) Open the DIN clip at the bottom of the module and clip the back of the module onto the DIN rail; 
3) If an expansion module is used, connect the flat cable of the expansion module to the expansion port under the front cover; 
4) Rotate the module close to the DIN rail and close the DIN clip; 
5) Carefully check whether the DIN clamp on the module is tightly fixed to the DIN rail; 
6) To avoid module damage, do not directly press the front of the module, but press the part of the installation hole
Attention: When the module is used in environments with high vibration or when installed vertically, DIN rail stops should be used. If the system is in a high vibration environment, using a backboard installation method can achieve a higher level of vibration protection.
 
Company Profile
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
Cotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLCCotrust Cth200 Profinet Slave Module Sm277pn36 Compatible Siemens PLC
FAQ

Q1.What's the payment term? 
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.

 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
2000000 RMB
Plant Area
>2000 square meters