Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust

Product Details
Customization: Available
Task: Program
Structure: Combination
Manufacturer/Factory
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
>2000 square meters
  • Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
  • Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
  • Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
CTS7 277-0AB32
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Weight
0.15kg
Electrical Interface
Isolated RS485
Maximum Number of Expansion Modules
6
Maximum Communication Speed
12Mbps
Transport Package
CTN
Specification
71*80*62mm
Trademark
COTRUST
Origin
China
HS Code
853710119
Production Capacity
5, 000 Pieces/Year

Product Description

 

 
Product Description
Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust

Order No.: CTS7 277-0AB32
Specification: CTSC-200 EM277B PROFIBUS-DP Slave Station Modules
Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust

Order No.: CTS7 277-0AA32
Specification: CTSC-200 EM277A PROFIBUS-DP Slave Station Modules

PROFIBUS-DP Slave Station Modules,communication rate up to 12Mbps.Isolation.

[Main feature]
Adopt a photoelectric isolation technique, high reliability and strong anti-interference ability.
Integrated terminal resistance, the bus adopt connection mode, no need dedicated network tap.
The power supply includes anti - access protection and Surge absorption function, it's suitable for bad industrial environment.
[Terms of use]
The signal wire should use shielded twisted pair wires, and the double end of the shielded wire should connect to the ground.
The grounding terminal should connect to the earth wire while the system is under good grounding cases.
If it's the last station, the terminal resistance should set to the ON position.
PROFIBUS-DP network
[Communication]
PROFIBUS-DP network connect to EM277A DP slave station module by its DP communication port, while EM277A DP slave station module connect to CTSC-200 CPU through serial I/O bus. EM277A use terminal to connect PROFIBUS network without using standard connector.
[Function]
EM277A is a modular slave station device for PROFIBUS DP networks that can connect up to 6 extended modules for digital or analog I/O.
As a DP slave station, the EM 277A module can run on any PROFIBUS baud rate between 9600 and 12M. Also receives a variety of I/O configurations and different amounts of data from the main station and sends data to the main station. The EM 277A can also read and write variable data blocks defined in the CTSC-200 CPU, allows user to exchange any type of data with master station.
MPI network
[Communication]
The EM277A module communicate with other master stations on the same network such as PG/PC programming station, Copanel HMI or S7-300/S7-400CPU as an MPI slave station. Use XGET/XPUT instruction function of S7-300/400 and other main station modules to provide the network communication between MPI main station and CTSC-200. When the EM277A module conducts MPI communication, the MPI master station must use its station address to send information to the CTSC-200 CPU. The MPI informationsent to the EM277A module will be transmitted to the CTSC-200 CPU via EM277A.
[Function]
EM277A is a slave station device for MPI networks that can connect up to 6 extension modules for digital or analog I/O.
As MPI slave station, the EM 277A module can be run at any MPI baud rate between 9600 and 12M. Also receives a variety of different I/O configurations and different amounts of data from the master station and sends data to the master station, and EM 277A can also read and write variable data blocks defined in the CTSC-200 CPU, allows the user to exchange any type of data with the master station.
Components of EM 277A
Status LED is located on the front of the module, address switch, terminal resistance switch ,DP slave interface terminal and user power supply are located on the side of wiring terminal, see as following figure:Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
  • Status LED
  • Terminal resistance switch: ON means with terminal resistance, OFF means without terminal resistance.
  • Isolated signal A
  • Isolated signal B
  • Isolated signal A
  • Isolated signal B
  • User Power supply
  • Address switch: Setup by 8 bits dial switch, and expressed in binary form, the available range is 0~126.  
  • Note  A1/B1 and A2/B2 are both RS-485 electric port, consistent internal electric characters, you can choose to connect one or two group.
  • PROFIBUS DP communication between S7-300 and EM277A of CTSC-200
    PROFIBUS DP communication between S7-300 and EM 277A of CTSC-200 need S7-300 station configuration in STEP7, no need to configure and program the communication in CTSC-200 system, just sort out the data to be communicated and store it in the V storage area corresponding to the hardware I/O address of S7-300 configuration EM 277A slave station.

    Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
    EM277B is a modular slave station device for PROFIBUS DP network, which communicates with the DP master station.EM277B can connect up to six extension modules for digital or analog input and output.EM277B USES terminals to connect PROFIBUS network instead of standard connectors, and baud rate is automatically adjusted to be consistent with the main station.

    [Main feature]
  • Photoelectric isolation technique, strong anti-interference ability, high reliability.
  • Power supply with reverse connection protection and surge absorption function, suitable for harsh industrial environments.
  • Construction of PROFIBUS-DP Network
  • Distributed I/O systems contain active (master) and passive (slave) nodes that are interconnected through PROFIBUS-DP.
    The following figure shows EM 277B in a typical PROFIBUS-DP network configuration:
    Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust1Status LED
    2Terminal resistance option switch: ON indicates with terminal resistance, OFF indicates without terminal resistance
    3Isolated signal A (network input)
    4Isolated signal B (network input)
    5Isolated signal A (network cascade)
    6Isolated signal B (network cascade)
    7User power
    8Sensor power
    9Address switch: set with 8 bit DIP switch, indicates in binary number, effective option range is 1-125
     Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
    Company Profile
    Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
    Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
Cts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, CotrustCts7 277-0ab32, PLC Module, Profibus-Dp Slave Interface Module, Photoelectric Isolation, Cotrust
FAQ

Q1.What's the payment term? 
A. We accept TT,LC,Western Union,Paypal.

Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.

Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.

Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.

Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.

Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.

Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
 

OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.

Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.

Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier