Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance Parameters
Physical Features | |||||||||||||||
Dimension(W×H×D) | 137×80×62mm | ||||||||||||||
Power consumption | 7W | ||||||||||||||
Program memory | 128K+64K+64K | ||||||||||||||
Data memory | 64KB+100KB,Data permanent stored | ||||||||||||||
Maximum number of expansion modules | 7 | ||||||||||||||
Maximum digital | 128DI/128DO(expand CAN expansion board up to 640DI/640DO) | ||||||||||||||
Maximum analog | 32AI/32AQ(expand CAN expansion board up to 194AI/194AO) | ||||||||||||||
Data stored | FlashROM Data permanent stored | ||||||||||||||
Power supply features | |||||||||||||||
Rated input voltage | DC24V | ||||||||||||||
Impulse current | 28.8VDC,12A | ||||||||||||||
Isolation (field and logic) | None | ||||||||||||||
Hold time (power off) | 10ms above | ||||||||||||||
Sensor +24V power output | Voltage range:20.4~28.8VDC | ||||||||||||||
Rated current:300mA | |||||||||||||||
Maximum ripple noise (<10MHz) :<1V peak-to-peak value | |||||||||||||||
Isolation (sensor and logic):Non | |||||||||||||||
Power alarm | when it is lower than 15V, the alarm bit SM195.1 | ||||||||||||||
Regular features | |||||||||||||||
Total timers | 512 | ||||||||||||||
1ms | 4 | ||||||||||||||
10ms | 272 | ||||||||||||||
100ms | 236 | ||||||||||||||
Counters | 256 | ||||||||||||||
Accumulators | 4 | ||||||||||||||
Memory bit | 256bit | ||||||||||||||
Local storage(L) | 64 bytes independent | ||||||||||||||
Sequence control relay(S) | 256 bit | ||||||||||||||
Time interrupt | 2*1ms resolutions | ||||||||||||||
Edge breaks | 8 | ||||||||||||||
Boolean operation execution time | ≤0.15us | ||||||||||||||
Floating operation execution time | ≤6.2us | ||||||||||||||
Real time clock | Built-in | ||||||||||||||
BD expansion board port | One ,BD expansion board supports RS485 expansion board, CAN expansion board, and analog expansion board | ||||||||||||||
System indicator | SF indicator (red) | ON:Program error,OFF:Normal | |||||||||||||
DIAG indicator (orange) | ON:Program control,OFF:Normal | ||||||||||||||
RUN indicator (green) | ON:running,OFF:stopped | ||||||||||||||
STOP indicator (orange) | ON:stopped,OFF:running | ||||||||||||||
RMC indicator (green) | ON:remote control is connected,OFF:remote control is disconnected | ||||||||||||||
LNK/ACT indicator (green) | ON:Ethernet connection,Blinking: Transmission ,OFF:disconnect | ||||||||||||||
Run switch | RUN/STOP | ||||||||||||||
External battery port | Special battery card | ||||||||||||||
Programming card | Support | ||||||||||||||
Integrated communication capabilities (PPI/ free port) | |||||||||||||||
Communication interface | 2 Communication port: PORT0:PPI/free port,standard RS485 PORT1:PPI/free port,standard RS485 After the RS485 expansion board is plugged in and restarted, PORT0 (RS485, PPI communication port) PORT1 (RS485, PPI/ free port), FPORT0 (free port) |
||||||||||||||
Baud rate(baud) | 9.6k,19.2k and 187.5k | ||||||||||||||
Free port baud rate(baud) | 1.2k ~ 115.2k | ||||||||||||||
Maximum number of stations | 32 stations per segment, 126 stations per network | ||||||||||||||
Maximum number of main stations | 32 | ||||||||||||||
Point-to-point (PPI master mode) | Yes(NETR/NETW),With a maximum of 8 connections and a maximum communication of 200 bytes per connection | ||||||||||||||
MPI connect | 8(1PG/1OP),2 reserved | ||||||||||||||
Maximum cable length per section Use an isolated repeater No isolated repeater is used |
The baud rate is 1000 m at 187.5 K and 1200 m at 38.4 K 50m |
||||||||||||||
Ethernet Communication | |||||||||||||||
Communication port | 1 Standard Ethernet port | ||||||||||||||
Communication standards | IEEE802.3 standards | ||||||||||||||
Transmission speed | 10Mbps/100Mbps adaptive | ||||||||||||||
Adaptive cross-connect | Support | ||||||||||||||
Hardware interface | RJ45 | ||||||||||||||
Protocol Type |
UDP/TCP protocol Supports UDP_PPI, MODBUS_TCP, Socket, and S7 protocols, Ethernet communication between PLCS, and MiCo Ethernet programming. |
||||||||||||||
Configuration mode |
Ethernet port search PLC,support the mouth download system configuration. |
||||||||||||||
Maximum number of connections | 8 UDP/PPI connections, no master or slave | ||||||||||||||
8 TCP/Modbus connections, no master or slave | |||||||||||||||
4 Socket connections, 2 UDP, 2 TCP | |||||||||||||||
8 S7 protocol, no master and slave, COTRUST PLC only as slave station | |||||||||||||||
Maximum single data transmission | Up to 200 bytes for UDP_PPI transmission. | ||||||||||||||
Up to 240 bytes are used for ModBus_TCP transmission. | |||||||||||||||
Up to 512 bytes is used for Socket transmission | |||||||||||||||
Up to 200 bytes for S7 transmission | |||||||||||||||
Startup time of network port | 5 to 10 seconds. The startup time varies depending on the network environment. | ||||||||||||||
Indicator | RMC | On: The remote server is successfully connected | |||||||||||||
Off: The remote connection is disconnected or the remote function is disabled | |||||||||||||||
LINK/ACT | On: The hardware of the network port is connected | ||||||||||||||
Blinking: Data is being exchanged | |||||||||||||||
Off: The hardware of the network port is disconnected | |||||||||||||||
The length of the communication cable | 100M,cable type is CAT5e or above | ||||||||||||||
Isolation | Communication isolation | ||||||||||||||
IP address reset function | Five consecutive times within two seconds | ||||||||||||||
Upgrade Firmware function | Use MagicWorks PLC and MiCo to remotely upgrade firmware from company servers over Ethernet | ||||||||||||||
I/O Features | |||||||||||||||
Number of integrated digital inputs | 14 | ||||||||||||||
Input type | Leak/Source | ||||||||||||||
Number of integrated digital outputs | 10 | ||||||||||||||
Output type | Source | ||||||||||||||
Maximum digital | 128DI/128DO(expand CAN expansion board up to 640DI/640DO) | ||||||||||||||
Maximum analog | 32AI/32AQ(expand CAN expansion board up to 194AI/194AQ) | ||||||||||||||
The maximum number of local expansion IO modules | 7 | ||||||||||||||
Pulse capture input | 14 | ||||||||||||||
High-speed counters | Total
Uniphase counters AB-phase counters |
6 6×50KHz 4×30KHz |
|||||||||||||
Integrated Communication Function (CANopen) - use for CAN communication board model CTH2-CAN-01S2-EB |
|||||||||||||||
Communication Interface |
1(8 Pin) |
||||||||||||||
Communication speed(kbps) | 1000 | 800 | 500 | 250 | 150 | 50 | 20 | ||||||||
Maximum cable length(m) | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 | ||||||||
Maximum station address | 127 | ||||||||||||||
Station address range | 1-127 | ||||||||||||||
Maximum number of master and slave stations | 32 | ||||||||||||||
Configuration method |
CAN configuration blocks and EDS files |
||||||||||||||
Maximum digital access | Nomal IO | CANopen IO | |||||||||||||
Byte | Memory starting address | Byte | Memory starting address | ||||||||||||
Input | 16 | IB0 | Input | 64 | IB16 | ||||||||||
Output | 16 | QB0 | Output | 64 | QB16 | ||||||||||
Maximum analog access | Normal IO | CANopen IO | |||||||||||||
Channel | Memory starting address | Channel | Memory starting address | ||||||||||||
Input | 32 | AIW0 | Input | 162 | AIW64 | ||||||||||
Output | 32 | AQW0 | Output | 162 | AQW64 | ||||||||||
Integrated Communication Function (CANFree) - Used when extending the CAN communication board | |||||||||||||||
Communication Protocol | CanFree | ||||||||||||||
Use method | Supported by internal library instructions | ||||||||||||||
Digital input features | |||||||||||||||
Number of interated digital input | 14 | ||||||||||||||
Input type | Leak/source | ||||||||||||||
Rated voltage | 24 VDC | ||||||||||||||
Maximum continuous allowable voltage | 30 VDC | ||||||||||||||
Logic 1 signal (min.) | 18 VDC,3.0mA | ||||||||||||||
Logical 0 signal (Max.) | 5 VDC,1mA | ||||||||||||||
Isolation (field and logic) Isolation group |
500 VAC,1min | ||||||||||||||
Simultaneously connected input | 14 | ||||||||||||||
Maximum cable length | 500m | ||||||||||||||
Shielding: 50 m (high speed counter input); Unshielded: 300 meters (standard input) | |||||||||||||||
Digital Output Features | |||||||||||||||
Number of integrated digital output | 10 | ||||||||||||||
Output type | Solid-MOSFET,source | ||||||||||||||
High speed pulse output |
3*100KHz motion control output(Q0.0,Q0.1,Q0.2) 2*20KHz PTO/PWM output(Q0.0,Q0.1) |
||||||||||||||
Output frequency (maximum) | 100KHz(Q0.0-Q0.2),1KHz(Q0.3-Q1.7) | ||||||||||||||
Rated voltage output | DC:24V | ||||||||||||||
Output voltage range | 20.4-28.8 VDC | ||||||||||||||
Rated current per point | 0.5A | ||||||||||||||
Rated current for each common point | 4A | ||||||||||||||
Leakage current (maximum) | 10µA | ||||||||||||||
Surge current | 8A,100ms | ||||||||||||||
Lamp load (maximum) | 5W | ||||||||||||||
On resistance (contact) | typical 0.3Ω,the max 0.6Ω | ||||||||||||||
Delay |
Off to on:2us(Q0.0, Q0.1, Q0.2),15us | ||||||||||||||
on to off:10us(Q0.0, Q0.1, Q0.2),130us | |||||||||||||||
Output of simultaneously connected | 10 | ||||||||||||||
Parallel output | Only when the outputs are in the same group | ||||||||||||||
Maximum cable length |
Shielde |
500m | |||||||||||||
Unshielded | 150m |
CTH2 216-1AD46-0X24 wiring diagram
RS485 communication port definition
Connector |
PIN |
PORT0(RS485) |
PORT1(RS485) |
|
1 |
Shell Grounded |
Shell Grounded |
2 |
logically |
logically |
|
3 |
RS485+signal B |
RS485+signal B |
|
4 |
Send the application |
Send the application |
|
5 |
+5V,Grounded |
+5V,100ΩGrounded |
|
6 |
+5V 100Ω |
+5V 100Ω |
|
7 |
+24V |
+24V |
|
8 |
RS485-signal A |
RS485-signal A |
|
9 |
NC |
NC |
|
shell |
Shell Grounded |
Shell Grounded |
RS485 expansion board communication interface
Module interface and connector |
PIN |
FPORT0(RS485) |
Note:when terminal resistors are needed, short connect the 2 and 3 pins |
1 |
RS485+signal B |
2 |
RS485-signalA |
|
3 |
Terminal resistance |
|
4 |
Shell Grounded |
|
5 |
RS485 signal GND |
|
6 |
NC |
|
7 |
NC |
|
8 |
NC |
|
9 |
NC |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.