Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Physical Features | ||||||||
Dimension(W×H×D) | 34×115×100 mm | |||||||
Power dissipation | 19.2W | |||||||
Power Supply Features | ||||||||
Rated input voltage | 24V DC | |||||||
Input voltage rang | 20.4V~28.8V DC | |||||||
Input current | 0.8A | |||||||
Polarity reverse connection protection | Yes | |||||||
Bus power supply voltage | +5V DC | |||||||
Bus power supply current | 1.6A | |||||||
LED Indicator Features | ||||||||
24V power indicator (green) | On: 24VDC power supply is normal; Off: No 24VDC power supply | |||||||
SF indicator(red) | On: system failure; Off: no fault | |||||||
BF indicator(red) | On: bus failure; Off: no fault | |||||||
FRCE indicator(yellow) | On: there is a mandatory item; Off: No item is forced (also can be controlled via the scrapers command) | |||||||
RMC indicator(green) | On: the remote server has been successfully communicated (Ethernet communication port parameters have been configured correctly); Off: failure to communicate with the remote server or disable communication with the remote server (allow and disable communication with the server via the dial switch control) | |||||||
RUN indicator(green) |
On:the system is running; Off: the system stops |
|||||||
STOP indicator(yellow) | On: the system stops; OFF = System running | |||||||
Link1 indicator(green) |
On: connection; Off: no connection |
|||||||
SPEED1 indicator(yellow) | On:100Mbps;Off:10Mbps | |||||||
Link2 indicator(green) | On: connection; Off: no connection | |||||||
SPEED2 indicator(yellow) | On:100Mbps;Off:10Mbps | |||||||
I0.0~I1.1(green) | On: there is a signal input; Off: no signal input | |||||||
Instruction performance | ||||||||
Bit instruction execution speed | 0.086µs/step | |||||||
Floating-point instruction execution speed | 1.4µs/step | |||||||
Memory | ||||||||
User program memory | 256KB+64KB(Secret memory) | |||||||
User data memory | 1MB | |||||||
Power down retention memory | 32KB | |||||||
Integrated communication function | ||||||||
Bus interface | provides extension module interface | |||||||
USB port | provides 1*USB main device interface | |||||||
EtherNET port | 1*EtherNET port | |||||||
RS485 port | 1*RS485 port | |||||||
EtherCAT port | 1*EtherCAT port | |||||||
CAN port | 1*CAN port | |||||||
RS485 port | ||||||||
Number of communication interfaces and protocols | 1*RS485 port,PPI/MPI,free port protocol (built-in MODBUS_RTU protocol) | |||||||
Free port baud rate | Baud rate 1.2Kbps~115.2Kbps,built-in Modbus master/slave function | |||||||
PPI/MPI baud rate | 9.6Kbps,19.2Kbps,187.5Kbps | |||||||
Maximum cable length per segment | Using isolation repeater: 1000m(187.2Kbps) | |||||||
1200m(38.4Kbps) | ||||||||
No isolation repeater used: 50M | ||||||||
Maximum number of stations | 32 for each segment and 126 for each network | |||||||
Point-to-point (PPI master mode) | Yes(NETR/NETW), with a maximum of 8 connections, each connection communicating a maximum of 200 bytes | |||||||
MPI connection | 1 MPI slave station and up to 8 MPI master stations | |||||||
Isolation | Communication port isolation | |||||||
CANopen port | ||||||||
Communication port | 1*CAN port | |||||||
Maximum number of slave stations | 1 master station can be followed by a maximum of 32 slave stations | |||||||
Protocol type | CANopen DS301 standard protocol | |||||||
Support function | Supports automatic starting of CANopen Manager | |||||||
Supports optional slave polling | ||||||||
Support to start slave stations | ||||||||
Support the NMT | ||||||||
Support synchronous production | ||||||||
Support synchronous consumption | ||||||||
Support heartbeat generation | ||||||||
Support activation time creation | ||||||||
Transmission rate(kbit/s) | 1000 | 1000 | 800 | 500 | 250 | 125 | 50 | 20 |
Maximum length (m) | 25 | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 |
Isolation | Communication port isolation | |||||||
EtherNET port | ||||||||
Communication port | 1*EtherNET port | |||||||
Baud rate | 10/100Mbps adaptive | |||||||
Protocol type | Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support S7 protocol, support Ethernet programming and Ethernet communication between CPU | |||||||
Maximum length of each cable | 100m connection directly | |||||||
Maximum number of connections per site | UDP_PPI supports a maximum of 8 connections | |||||||
ModBus_TCP supports up to 32 connections, | ||||||||
Socket supports up to 4 connections | ||||||||
2 UDP, and 2 TCP | ||||||||
User data number | Up to 200 bytes for UDP_PPI transmission | |||||||
Up to 240 bytes are used for ModBus_TCP transport | ||||||||
Maximum of 512 bytes are used for Socket transmission | ||||||||
DHCP function | Support | |||||||
Remote monitoring/programming support | Support | |||||||
Isolation | Communication port isolation | |||||||
EtherCAT port | ||||||||
Communication port | 1*EtherCAT port | |||||||
Baud rate | 100Mbps adaptive | |||||||
Protocol type | EtherCAT communication protocol | |||||||
Maximum length of each cable | 100m connection directly | |||||||
Maximum number of connections per site | Each master supports up to 64 EtherCAT slave stations | |||||||
Support function | Support for distributed clock configuration, redundancy settings | |||||||
Support startup parameter configuration | ||||||||
Support for configuring PDO parameters and mappings | ||||||||
Support for configuring bus cycle cycle, configuring startup check vendor ID and product ID | ||||||||
Programming software | ||||||||
Programming software package | Magicworks PLC V2.19 and above version | |||||||
Programming language | LAD,STL,C language | |||||||
Program organization unit | ||||||||
Block types | Maximum number | maximum capacity per block | Maximum memory | |||||
Organization block OB | total number of OB tissue blocks is up to 1024 | 64KB | 256KB+64KB | |||||
Function FC | 64KB | |||||||
Function block FB | 64KB | |||||||
Data blocks DB | 256 | 64KB | 1M | |||||
Protection function | ||||||||
Power supply protection | Power supply provides reverse connection protection function and surge absorption function | |||||||
Interface protection | Communication port lightning protection | |||||||
Local I/O expand capabilities | ||||||||
Maximum number of racks | 4 | |||||||
Maximum number of modules | Main rack extensions: 11 (power module, CPU, relay module, 8 signal modules) Slave rack:10(power module, relay module, 8 signal modules) | |||||||
Remote I/O expansion capabilities | ||||||||
CAN extends the maximum number of master stations | 8 | |||||||
Maximum number of CAN slave stations | Each master station CAN connect up to 32 CAN slave stations (277C) | |||||||
Maximum number of EtherCAT extended slave station | Connect up to 64 EtherCAT slave modules, each EtherCAT slave module has a maximum of 8 signal modules | |||||||
Support motion control function | ||||||||
Motion control function | Conforms to the single axis motion control function of PLCopen standard (positioning, speed and return to the original, etc.), linear/arc interpolation function, continuous interpolation function, electronic CAM, electronic gear function. | |||||||
Support high-level language functions | ||||||||
High-level language | Supports C language programming capabilities | |||||||
Data area and retention features | ||||||||
Data area type | Size | Addressing range | Addressing property | Access property | Hold property | |||
Digital Volume Map(I) | 256bytes | IB0-IB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
Digital volume(Q) | 256bytes | QB0-QB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
Analog volume (AI) | 1024bytes | AIW0-AIW1022 | Read only | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
Analog volume(AQ) | 1024bytes | AIW0-AIW1022 | Write only | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
Variable memory(V) | 65536bytes | VB0-VB65535 | Read/write | Direct access/indirect access | Support power down hold data | |||
Special memory Area (SM) | 2048bytes | SMB0-SMB2047 | SMB0-SMB29 Read Only/SMB30-SMB2047 Read/write | Direct access/indirect access | Power down hold data are not supported | |||
Bit memory(M) | 32bytes | MB0-MB31 | Read/write | Direct access/indirect access | Support power down hold data | |||
Local variable(L) | 128bytes | LB0-LB127 | Read/write | Direct access | Startup to stop the same call position subroutine can be keep,power down hold data are not supported | |||
Accumulator register(AC) | 4 | AC0-AC3 | Read/write | Direct Access | Power down hold data are not supported | |||
Step register(S) | 32bytes | SB0-SB31 | Read/write | Direct access/indirect access | Power down hold data are not supported | |||
Timer(T) | 1ms*36 | T0-T2047 | - | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold | |||
10ms*752 | ||||||||
100ms*1260 | ||||||||
Counter(C) | 2048 | C0-C2047 | - | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold | |||
Data block(DB) | 512KB | - | Read/write | Direct access/indirect access | 16KB power down hold data | |||
Diagnostic function | ||||||||
Number of diagnostic event buffer bars | 500, and the oldest one is overwritten when the buffer is full | |||||||
Number of diagnostic event power down hold | 500 | |||||||
The event recording accuracy | 1ms | |||||||
Diagnostic interrupt | Support | |||||||
Diagnostic LED indication | Support | |||||||
Real time clock | ||||||||
Power-down retention time | Power-down retention time is about 112 hours (typical value), and the power-down retention time can reach at least 1 year after H56 is connected with external battery | |||||||
Accuracy | Less than 60 seconds per month | |||||||
Interrupt | ||||||||
Timed interrupt | 4 | |||||||
Input interrupt | 10 | |||||||
High speed counter interrupt | 6 | |||||||
Digital input features | ||||||||
Integrated IO | 10 | |||||||
Input type | Leak/source | |||||||
Rated voltage | 24V DC | |||||||
Input voltage range | 20.4~28.8V DC | |||||||
Surge voltage | 35V DC,last for 0.5s | |||||||
Logic 1 signal (min.) | 15 VDC,2.5mA | |||||||
Logic 0 signal (Max) | 5 VDC,1mA | |||||||
Connect 2-wire proximity switch sensor (BERO) | 1mA(maximum allowable leakage current) | |||||||
Input filtering | Support 0.2us,0.4us,0.8us,1.6us,3.2us,6.4us,12.8us,0.2ms,0.4ms,0.8ms,1.6ms,3.2ms,6.4ms,12.8ms,default is 6.4ms | |||||||
Isolation (field and logic) | 500V AC,1min | |||||||
Isolation group | See wiring diagram | |||||||
Simultaneous connection input | 10 | |||||||
Maximum cable length | 500m(standard input) | |||||||
Shielded | 50m(high speed counter input) | |||||||
Unshielded | 300m(standard input) | |||||||
Pulse capture input | 10 | |||||||
High speed counter | Total | 6 | ||||||
Single phase | 6×500KHz | |||||||
Two phase | 4×250KHz |
Power interface definition
4pin terminals spaced at 3.81mm apart |
Symbol |
Signal definition |
|
L+ |
+24V power positive |
M |
+24V power negative |
|
|
+24V power ground |
|
-- |
-- |
USB interface definition
USB port |
No. |
Signal |
Signal definition |
1 |
V_BUS |
+5V power |
|
2 |
Data- |
Data- |
|
3 |
Data+ |
Data+ |
|
4 |
GND |
Ground |
EtherNET interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
TX+ |
Positive end of data transmission |
2 |
TX- |
Negative end of data transmission |
|
3 |
RX+ |
Positive end of data transmission |
|
4 |
TERM |
-- |
|
5 |
TERM |
-- |
|
6 |
RX- |
Negative end of data transmission |
|
7 |
TERM |
-- |
|
8 |
TERM |
-- |
|
Shell |
PE |
Shell ground |
|
Green indicator |
As an indication of EtherNET connection status |
||
Yellow indicator |
As an indication of EtherNET connection status |
RS485/CAN interface definition
RJ45 port |
No. |
Signal |
Signal definition |
|
1 |
CAN_H |
Positive end of data transmission |
2 |
CAN_H |
Negative end of data transmission |
|
3 |
- |
-- |
|
4 |
A0 |
RS485 signal A |
|
5 |
B0 |
RS485 signal B |
|
6 |
- |
-- |
|
7 |
CAN_GND |
CAN_GND signal Ground |
|
8 |
- |
-- |
|
Shell |
PE |
Shell ground |
Dial switch definition
Dial switch |
Symbol |
Dial direction |
Signal definition |
RUN |
Up |
System operation |
|
STOP |
Down |
System halt |
|
Swivel 5 times in 3 seconds |
Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
OEM Services
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.